• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Fri, 05.12.25

Search results


November 2024
Ronit Lev Kolnik MD, Idan Bergman MD, Avishay Elis MD

Background: The Agatston coronary artery calcium (CAC) score is a decision-guiding aid for risk assessment and personalized management in the primary prevention of atherosclerotic cardiovascular disease.

Objectives: To explore the real-life clinical experience of CAC testing by characterizing its indications, significance of scores, and corresponding lipid-lowering treatments.

Methods: A retrospective descriptive study of patients treated at the lipids clinic at Rabin Medical Center (Beilinson Campus), who underwent CAC score evaluation between 2017 and 2022 was conducted. The data collected from electronic medical files included demographics, co-morbidities, indications for the test, CAC score levels, and the recommended therapeutic regimen.

Results: The study cohort included 88 patients. The main indication was assessment of the existence of atherosclerosis in cases where there was no clear indication for lipid lowering treatment (65, 74%). In most patients, there was no evidence of atherosclerosis (CAC = 0 AU, n=30) or only mild disease (CAC=1–99 AU, n=35). As the CAC score increased, more patients were prescribed lipid lowering treatments, from very few prescriptions in those with a CAC score of 0 AU and almost 100% among those with score of ≥ 400 AU. The factors that predicted CAC > 0 AU were male sex and older age.

Conclusions: CAC scores should be used more often to determine risk assessment. Further analysis of the implications of scores between 0–400 AU is needed.

April 2024
Ruba Tuma MD, Marwan Odeh MD, Maya Wolf MD, Inshirah Sgayer MD, Nicola Luigi Bragazzi MD PhD, Rola Khamisy-Farah MD

Background: The cavum septi pellucidi (CSP) is a brain-enclosed cavity located on the midline between the two leaflets of the septum pellucidum that separates the lateral ventricles. This structure develops in the fetus from week 18 and can be seen up to week 37 in almost all cases and then begins to disappear.



Objectives: To measure and determine the normative values of the CSP volume in fetuses between 20 to 40 weeks of gestation.

Methods: The study comprised 161 consecutive pregnant women between 20 to 40 weeks of gestation with single viable fetuses. All patients had normal, disease-free pregnancies. Transvaginal or transabdominal ultrasound was used according to the fetal presentation. The fetal head was assessed in mid-sagittal sections. Once the CSP was visualized, its volume was measured using three-dimensional ultrasound with Virtual Organ Computer-aided Analysis software. The width of the CSP was also measured at the biparietal diameter (BPD) plane.

Results: Of the 161 fetuses, the CSP volume was measured in 158. In three patients the CSP was not identified. The CSP volume correlated poorly with gestational age (r=0.229) and with the BPD (r=0.295). The mean CSP volume was 0.508 ± 0.372 ml (range: 0.03-1.78 ml). The simple measurement of the CSP width correlated better with gestational age (r=0.535) and the BPD (r=0.484).

Conclusions: The CSP volume had a poor correlation with gestational age; however, the volume did not exceed 2 ml regardless of gestational age. This information can be used to assess pathologies involving the CSP.

 

December 2022
Ayelet Shles MD, Giulia Pula MD, Omer Raviv MD, Dania Takagi MD, Hadas Yechiam MD, Ehud Rosenbloom MD

Background: Blood pressure (BP) is routinely measured while triaging children presenting to the pediatric emergency department (PED).

Objectives: To determine whether a medical clown shortens the time to acquire a BP measurement among children undergoing triage in the PED.

Methods: The study comprised 133 children. Patients were assigned to one of two groups: with a medical clown or without a medical clown.

Results: The presence of a medical clown led to a significantly shorter time to acquire a blood pressure measurement (60 ± 23 seconds vs. 81 ± 43.5 seconds, P < 0.001. Clowns had a significant effect on shortening total triage length among children of Jewish ethnicity compared to Arab ethnicity (113 ± 353.6 seconds vs. 154 ± 418 seconds, P = 0.012).

Conclusions: Using medical clowns while measuring BP during triage when used in a culturally appropriate manner shortens time.

March 2018
Narin N. Carmel-Neiderman MD, Idan Goren MD, Yishay Wasserstrum MD, Tal Frenkel Rutenberg MD, Irina Barbarova MD, Avigal Rapoport MD, Dor Lotan MD, Erez Ramaty MD, Naama Peltz-Sinvani MD, Adi Brom MD, Michael Kogan MD, Yulia Panina MD, Maya Rosman MD, Carmel Friedrich MD, Irina Gringauz MD, Amir Dagan MD, Iris Kliers MD, Tomer Ziv-Baran PhD and Gad Segal MD

Background: Accurate pulse oximetry reading at hospital admission is of utmost importance, mainly for patients presenting with hypoxemia. Nevertheless, there is no accepted or evidence-based protocol for such structured measuring.

Objectives: To devise and assess a structured protocol intended to increase the accuracy of pulse oximetry measurement at hospital admission.

Methods: The authors performed a prospective comparison of protocol-based pulse-oximetry measurement with non-protocol based readings in consecutive patients at hospital admission. They also calculated the relative percentage of improvement for each patient (before and after protocol implementation) as a fraction of the change in peripheral capillary oxygen saturation (SpO2) from 100%.

Results: A total of 460 patients were recruited during a 6 month period. Implementation of a structured measurement protocol significantly changed saturation values. The SpO2 values of 24.7% of all study participants increased after protocol implementation (ranging from 1% to 21% increase in SpO2 values). Among hypoxemic patients (initial SpO2 < 90%), protocol implementation had a greater impact on final SpO2 measurements, increasing their median SpO2 readings by 4% (3–8% interquartile range; P < 0.05). Among this study population, 50% of the cohort improved by 17% of their overall potential and 25% improved by 50% of their overall improvement potential. As for patients presenting with hypoxemia, the median improvement was 31% of their overall SpO2 potential.

Conclusions: Structured, protocol based pulse-oximetry may improve measurement accuracy and reliability. The authors suggest that implementation of such protocols may improve the management of hypoxemic patients.

Ran Nagar MD, Sharon Perlman MD, Or Yariv MD, Zvi Kivilevich MD, Benjamin Dekel MD PhD, Reuven Achiron MD and Yinon Gilboa MD

Background: Sonographic assessment of the fetal kidneys is an integral part of the prenatal anatomical survey.

Objectives: To evaluate the fetal renal to abdominal (RTA) ratio throughout pregnancy and to investigate whether this ratio can be a potential diagnostic landmark for congenital anomalies of the kidney and urinary tract (CAKUT).

Methods: Measurements of the anterior-posterior diameters of the fetal kidney and fetal abdomen (APAD) were obtained prospectively. The RTA was calculated as the ratio between them in in two groups: normal population vs. CAKUT cases. RTA in CAKUT cases was compared to RTA in a normal population.

Results: The study group was comprised of 210 women. The mean gestational age for the fetuses was 31 ± 5.6 weeks (range 14–40 weeks). Fetal RTA ratio was found to be 0.28 ± 0.03 throughout pregnancy from early second trimester to term, with high reproducibility of measurements. During the study period the RTA was evaluated in nine cases referred for suspected CAKUT. All cases demonstrated a different ratio according to the renal anomaly. High ratio was observed in one case of overgrowth syndrome (Beckwith Wiedenmann syndrome; 0.47), three cases of infantile polycystic kidney (0.45–0.47), and three cases of a solitary kidney (0.31–0.35), while cases of dysplastic kidneys revealed a low ratio (0.14–0.18).

Conclusions: Prenatal RTA ratio is constant throughout gestation. An abnormal ratio should lead to meticulous renal investigation to rule out kidney disease.

June 2010
A. Itsekson, D. Shepshelovich, A. Kanevsky and D.S. Seidman
Background: Non-invasive screening tests may allow early diagnosis and prompt treatment, thereby potentially reducing morbidity and mortality and reducing costs for the community.  This may be especially important for gynecologic pathologies that are difficult to promptly diagnose, such as endometriosis or ovarian cancer.

Objectives: To evaluate the reliability of measuring skin resistance using the Medex Test for screening and diagnosis of gynecologic pathologies in a blinded single-center study.

Methods: We enrolled 150 patients: 59 with a functional disorder and 91 with an organic disease. Measurements were carried out in all patients and the results were analyzed separately by a second physician who was blinded to the patients’ diagnosis.

Results: A high correlation was found between the clinical diagnosis and the results of the measurement of electrical skin resistance, with a specificity of 76.3% (45/59) for functional disorders and a sensitivity of 85.7% (78/91) for organic disorders, positive predictive value of 84.8% (78/92) and negative predictive value 77.6% (45/58). The kappa value for the results was 0.622, representing a value much better than expected randomly.

Conclusions: The Medex Test has a good specificity and a high sensitivity for the diagnosis of gynecologic disorders. Further prospective studies are needed to validate these preliminary findings.

April 2010
M. Cohen-Cymberknoh, D. Shoseyov, S. Goldberg, E. Gross, J. Amiel and E. Kerem

Pathological gambling is classified in the DSM-IV-TR (Diagnostic and Statistical Manual of Mental Disorders) and in the ICD-10 (International Classification of Disease) as an impulse control disorder. The association between impulsivity and pathological gambling remains a matter of debate: some researchers find high levels of impulsivity within pathological gamblers, others report no difference compared to controls, and yet others even suggest that it is lower. In this review we examine the relationship between pathological gambling and impulsivity assessed by various neurocognitive tests. These tests – the Stroop task, the Stop Signal Task, the Matching Familiar Figures Task, the Iowa Gambling Task, the Wisconsin Card Sorting Test, the Tower of London test, and the Continuous Performance Test – demonstrated less impulsivity in gambling behavior. The differences in performance between pathological gamblers and healthy controls on the neurocognitive tasks could be due to addictive behavior features rather than impulsive behavior.

October 2005
E. Zimlichman, A. Lahad, A. Aron-Maor, A. Kanevsky and Y. Shoenfeld.
 Background: As complementary and alternative medicine is gaining popularity among health consumers, diagnostic screening tools based on neuroreflexology are also being developed. These techniques, which are based on the rationale that measurement of electrical impedance of specific dermatomes reflects corresponding internal organ pathologies, have not yet been the subject of conventional scientific research.

Objectives: To determine the effectiveness of a neuroreflexology-based screening test, specifically the Medex device (Medex Screen Ltd.), for diagnosing patients undergoing conventional internal organ assessment, in a hospital setting.

Methods: Patients admitted to an internal medicine department, who met the inclusion criteria and agreed to participate, underwent conventional medical evaluation that included past medical history and physical examination. Another examination was conducted by a second physician using the Medex device to determine internal organ pathologies. A third researcher compared the actual “conventional” diagnosis with the Medex device output using standard statistical analysis.   

Results: Overall, 150 patients participated in the study. Correlation was significant for all categories (P < 0.01) except for blood and lymphatic disease. A high sensitivity (>70%) was measured for cardiovascular, respiratory, gastrointestinal and genitourinary diseases. The highest measure of agreement, as represented by the Cohen-Kappa factor, was found for respiratory disease (0.57).

Conclusions: Although the exact mechanism is not entirely clear, measurement of electroskin impedance of dermal-visceral zones has the potential to serve as a screening tool for inner organ pathologies. Further research should be conducted to create more evidence to support or dispute the use of this technique as a reliable diagnostic tool.

November 2003
A. Halevy, A. Stepanasky, Z. Halpern, I. Wasserman, Z. Chen-Levy, S. Pytlovich, O. Marcus, A. Mor, P. Hagag, T. Horne, S. Polypodi and J. Sandbank

Background: Among the various new technologies in the field of parathyroid surgery are intraoperative quick parathormone measurements.

Objectives: To evaluate the contribution of QPTH[1] measurements during parathyroidectomy to the achievement of higher success rates. 

Methods: QPTH assay using Immulite Turbo Intact PTH[2] was measured in 32 patients undergoing parathyroidectomy: 30 for primary and 2 for secondary hyperparathyroidism.  QPTH levels were measured at time 0 minutes (before incision) and at 10, 20, and 30 minutes after excision of the hyperfunctioning gland.  Only a drop of 60% or more from the 0’ level was considered to be a positive result.

Results: The mean QPTH level at time 0’ for PHPT[3] patients was 38.12 ± 25.15 pmol/L (range 9.1–118 pmol/L).  At 10 minutes post-excision of the hyperfunctioning gland (or glands), QPTH dropped by a mean of 73.80% to 9.89 ± 18.78 pmol/L. 

Conclusions: Intraoperative QPTH level measurement is helpful in parathyroid surgery.  A drop of 60% or more from 0’ level indicates a successful procedure, and further exploration should be avoided.






[1] QPTH = quick parathormone



[2] PTH = parathormone



[3] PHPT = primary hyperparathyroidism


January 2003
J. Shemer, N. L. Friedman, E. Kokia

This paper describes "Health Value Added" – an innovative model that links performance measurement to strategy in health maintanance organizations. The HVA[1] model was developed by Maccabi Healthcare Services, Israel’s second largest HMO[2], with the aim of focusing all its activities on providing high quality care within budgetary and regulatory constraints. HVA draws upon theory and practice from strategic management and performance measurement in order to assesses an HMO’s ability to improve the health of its members. The model consists of four interrelated levels – mission, goals, systems, and resources – and builds on the existence of advanced computerized information systems that make comprehensive measurements available to decision makers in real time. HVA enables management to evaluate overall organizational performance as well as the performance of semi-autonomous units. In simple terms, the sophisticated use of performance measures can help healthcare organizations obtain more health for the same money.






[1] HVA = Health Value Added



[2] HMO = health maintenance organization


Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel