December 2015
Yuval Konstantino MD, Tali Shafat BSc, Victor Novack MD PhD, Lena Novack PhD and Guy Amit MD MPH
 

Background: Implantable cardioverter defibrillators (ICDs) reduce mortality in patients implanted for primary and secondary prevention of sudden cardiac death. Data on the incidence of appropriate ICD therapies in primary vs. secondary prevention are limited. 


Objectives: To compare ICD therapies and mortality in primary vs. secondary prevention of sudden cardiac death. 


Methods: We conducted a retrospective analysis of 581 consecutive patients receiving an ICD for primary (66%) or secondary (34%) prevention indications. 


Results: During long-term follow-up, 29% of patients implanted for secondary prevention received appropriate ICD therapy vs. 18% implanted for primary prevention. However, the overall 7 year mortality rate was not significantly different between the two groups (26.9%, P = 0.292). Multivariate analysis showed that patients implanted for primary prevention had a significantly lower risk of appropriate ICD therapy even after adjustment for age, left ventricular ejection fraction < 0.35 and chronic renal failure (HR 1.63, 95%CI 1.10–2.41, P = 0.015).


Conclusions: Patients implanted for secondary prevention were more likely to receive appropriate ICD therapy, with a significantly shorter time period from ICD implant to the first therapy. However, all-cause mortality was comparable between primary and secondary prevention groups. 


 

 
April 2013
N. Yanculovich, Z.H. Perry, R. Gurfinkel and L. Rosenberg

 Background: Burn injuries are extremely common and may impose a serious load on public health around the world.

 Objectives: To compare mortality rates and length of hospitalization according to the identified risk factors, extent of burn, gender and age.

Methods: In this retrospective study, data from 558 archive files of hospitalization due to burns as the diagnosis in patients of all ages, between the years 2001 and 2002, were analyzed to identify the risk factors for mortality and length of hospitalization.

Results: Males comprised 62.4% of the hospitalized burn patients. The mortality rate was 3.2% (n=18) and among them 55.6% were women. Fifty percent of the fatality cases were over 48 years old, with statistically significant correlation of mortality rate and age. Most of the fatality cases (66.7%) had burns with total burn surface area (TBSA) larger than 40%. The multiple logistic regression model showed that leukocyte count on admission, TBSA, and age are the most important predictors of mortality. Smoke inhalation was not found to be an independent risk factor.

Conclusions: Using a statistical model for estimating the mortality rate, this study found that white blood cell count at admission, TBSA, and age were the most significant predictors of mortality. 

November 2012
June 2012
P. Codner, R. Nevzorov, J. Kusniec, M. Haim, R. Zabarski and B. Strasberg

Background: Defibrillation threshold (DFT) testing at the time of implantable cardioverter defibrillator (ICD) insertion is performed routinely. Recently this practice is being reconsidered due to doubts about its ability to improve ICD efficacy and evidence that survival may not be affected by the test.

Objectives: To compare the outcome of ICD recipients who underwent DFT testing and those in whom no testing was performed.

Methods: A total of 213 eligible patients were implanted with an ICD between 2004 and 2009. DFT testing was performed in 80. We compared total mortality, appropriate and inappropriate ICD shocks, and anti-tachycardia pacing (ATP) events between DFT and non-DFT patients during a follow-up of 2 years.

Results: On comparing the DFT and non-DFT groups, we found a 2 year mortality rate of 7.5% versus 8.3%, respectively (P = 0.8). Furthermore, 20.7% of patients in the DFT group and 12.4% in the non-DFT group had at least one episode of ICD shock (P = 0.15). With regard to ICD treatment (ICD shocks or ATP events), 57.7% in the DFT group and 64.2% in the non-DFT group received appropriate treatments (P = 0.78).

Conclusions: No significant differences in the incidence of 2 year mortality or percentage of ICD treatment emerged between the DFT and non-DFT groups.
 

December 2009
October 2009
T. Fuchs and A. Torjman

Background: Patients with hypertrophic cardiomyopathy are prone to ventricular arrhythmias and sudden death. Identifying patients at risk of sudden death is difficult.

Objectives: To determine whether microvolt T-wave alternans detected during exercise or rapid atrial pacing can identify patients with HCM[1] who are at risk of ventricular arrhythmias and sudden death.

Methods: This prospective observational study included 21 patients with HCM: 11 with hypertrophic obstructive cardiomyopathy, 9 with non-obstructive hypertrophic cardiomyopathy, and 1 with apical hypertrophic cardiomyopathy. TWA[2] was measured while the patients were on anti-arrhythmic medication.

Results: TWA was positive in 9 patients (43%) and negative in 12 (57%). Three patients were resuscitated after sudden death before their enrolment in the study and two patients developed ventricular tachycardia and fibrillation respectively during the study period. After combining the endpoint of sudden death from a ventricular arrhythmia and the presence of ventricular arrhythmias on a Holter monitor, there was no significant correlation between the presence of a positive TWA and the presence of ventricular arrhythmias on the Holter monitor or a history of sudden death.  

Conclusion: TWA cannot be used as a non-invasive test for detecting patients with HCM and electrical instability. TWA is not useful for predicting sudden death in patients with HCM.






[1] HCM = hypertrophic cardiomyopathy



[2] TWA = T-wave alternans


June 2008
R. Rosso, A. Click, M. Glikson, M. Swissa, S. Rosenhek, I. Shetboun, V. Khalamizer, M. Boulos, M. Geist, B. Strasberg, M. Ilan and B. Belhassen

background: many electrophysiologists recommend implantable cardioverter defibrillators for patients with Brugada syndrome who are cardiac arrest survivors or presumed at high risk of sudden death (patients with syncope or a familial history of sudden death or those with inducible ventricular fibrillation at electrophysiologic study).

objectives: To assess the efficacy and complications of ICD therapy in patients with Brugada syndrome.

Methods: The indications, efficacy and complications of ICD therapy in all patient with Brugada syndrome who underwent ICD implantation in 12 Israeli centers between 1994 and 2007 were analyzed.

Results: there were 59 patients (53 males, 89.8%) with a mean age of 44.1 years. At diagnosis 42 patients (71.2%) were symptomatic while 17 (28.8%) were asymptomatic. The indications for ICD implantation were: a history of cardiac arrest (n=11, 18.6%), syncope (n=31, 52.5%), inducible VF in symptomatic patients (n=14, 23.7%), and a family history of sudden death (n=3, 0.5%). The overall inducibility rates of VF were 89.2% and 93.3% among the symptomatic and a symptomatic patients, respectively (P=NS). During a follow-up of 4-160 (45+-35) months, all patients (except one who died from cancer) are alive. Five patients (8.4%), all with a history of cardiac arrest, had appropriate ICD discharge. Conversely, none of the patients without prior cardiac arrest had appropriate device therapy during 39+-30 month follow-up. Complications were encountered in 19 patients (32%). Inappropriate shocks occurred in 16 (27.1%) due to lead failure/dislodgment (n=5), T wave oversensing (n=2), device failure (n=1), sinus tachycardia (n=4), and supraventricular tachycardia (n=4). One patient suffered a pneumothorax and another a brachial plexus injury during the implant procedure. One patient suffered a late (2 months) perforation of the right ventricle by the implanted lead. Eleven patients (18.6%) required a reintervention either for infection (n=1) or lead problems (n=10). Eight patients (13.5%) required psychiatric assistance due to complications related to the ICD (mostly inappropriate shocks in 7 patients).

Conclusions: In this Israeli population with Brugada syndrome treated with ICD, appropriate device therapy was limited to cardiac arrest survivors while none of the other patients including those with syncope and/or inducible VF suffered an arrhythmic event. The overall complication rate was high.
 

August 2007
M. Garcia-Carrasco, R.O. Escarcega, C. Mendoza-Pinto, A. Zamora-Ustaran, I. Etchegaray-Morales, J. Rojas-Rodriguez, L.E. Escobar-Linares and R. Cervera
November 2006
Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel