March 2017
Uri Landes MD, Arthur Kerner MD, Amit Segev MD, Haim Danenberg MD, Yaron Shapira MD, Ariel Finkelstein MD and Ran Kornowski MD FESC FACC

Background: Transcatheter tricuspid valve-in-valve implantation (TVIV) is an attractive yet under-explored alternative to redo valve surgery. 

Objectives: To report the multicenter TVIV experience in Israel.

Methods: We approached multiple centers and collected data regarding seven TVIV cases. 

Results: The study group comprised seven participants: five females and two males, with a mean age of 63 ± 12 years and EuroSCORE-II 13.6 ± 3.3%. Follow-up ranged from 3 to 21 months (mean 8 ± 6 months). All presented with advanced heart failure. The indication for valve intervention was a predominant tricuspid stenosis in three patients, significant tricuspid regurgitation in one and a mixture in three. Six procedures were conducted via a transfemoral approach and one by transatrial access. The Edwards SAPIENTM XT valve was used in four cases and the SAPIENTM 3 in three. Without pre-stenting/rapid pacing, all participants underwent successful valve implantation. Mean transvalvular gradient decreased from 11 ± 3 mmHg to 6 ± 3 mmHg (P = 0.003) and regurgitation decreased from moderate/severe (in four cases) to none/trace (in six of the seven cases). One patient remained severely symptomatic and died 3.5 months after the implantation. All others achieved a functional capacity improvement and amelioration of symptoms soon after the implantation, which persisted during follow-up. 

Conclusions: TVIV may be a safe and effective strategy to treat carefully selected patients with degenerated bioprosthetic tricuspid valve at high operative risk. 

 

January 2016
Eyal R. Nachum MD, Ehud Raanani MD, Amit Segev MD, Victor Guetta MD, Ilan Hai MD, Amihai Shinfeld MD, Paul Fefer MD, Hamdan Ashraf MD, Israel Barabash MD, Amjad Shalabi MD and Dan Spiegelstein MD

Background: The rate of mitral bioprosthesis implantation in clinical practice is increasing. Transcatheter valve-in-valve implantation has been described for high risk patients requiring redo valve surgery. 

Objectives: To report our experience with transapical valve-in-valve implantation for failed mitral bioprosthesis.

Methods: Since 2010, 10 patients have undergone transapical valve-in-valve implantation for failed bioprosthesis in our center. Aortic valve-in-valve implantation was performed in one of them and mitral valve-in-valve implantation in nine. Mean age was 82 ± 4 years and 6 were female (67%). Mean time from original mitral valve (MV) replacement to valve-in-valve procedure was 10.5 ± 3.7 years. Follow-up was completed by all patients with a mean duration of 13 ± 12 months. 

Results: Preoperatively, all patients presented with significant mitral regurgitation; two with mitral stenosis due to structural valve failure. All nine patients underwent successful transapical valve-in-valve implantation with an Edwards Sapien™ balloon expandable valve. There was no in-hospital mortality. Mean and median hospital duration was 15 ± 18 and 7 days respectively. Valve implantation was successful in all patients and there were no major complications, except for major femoral access bleeding in one patient. At last follow-up, all patients were alive and in NYHA functional class I or II. Echocardiography follow-up demonstrated that mitral regurgitation was absent or trivial in seven patients and mild in two. At follow-up, peak and mean gradients changed from 26 ± 4 and 8 ± 2 at baseline to 16.7 ± 3 and 7.3 ± 1.5, respectively.

Conclusions: Transcatheter transapical mitral valve-in-valve implantation for failed bioprosthesis is feasible in selected high risk patients. Our early experience with this strategy is encouraging. Larger randomized trials with long-term clinical and echocardiographic follow-up are recommended.

 