IMAJ | volume

Journal 2, February 2000
pages: 122-125

Comparison of Assays for Anti-endomysial and Anti- transglutaminase Antibodies for Diagnosis of Pediatric Celiac Disease

    Summary

    Background: Anti-endomysial antibodies are sensitive and specific markers for celiac disease. This antibody has recently been identified as an antibody to tissue transglutaminase, an enzyme that cross-links and stabilizes extracellular matrix proteins.

    Objectives: To evaluate the clinical usefulness of an enzyme-linked immunoassay for anti-transglutaminase antibodies, and to compare the results with those of AEA, the current gold standard serological test for celiac disease.

    Methods: Serum samples were collected from 33 patients with biopsy-proven celiac disease and AEA tests were performed. Control samples for anti-transglutaminase were obtained from 155 patients. An ELISA test for immunoglobulin A anti-transglutaminase utilizing guinea pig liver transglutaminase was developed and performed on all sera.  Cutoff values for the test were performed using logistic regression and receiver operating curves analysis.

    Results: An optical density cutoff value of 0.34 was established for the assay. The mean value was 0.18±0.19 optical density for controls, and 1.65±1.14 for patients with celiac disease (P<0.001). Sensitivity and specificity of the assay were both 90%, while AEA had a sensitivity and specificity of 100% and 94%, respectively.

    Conclusions: A tissue transglutaminase-based ELISA test is both sensitive and specific for  detection of celiac disease.

    __________________________________

     

    AEA = anti-endomysial antibody