• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Sun, 28.04.24

Original Articles

IMAJ | volume 12

Journal 8, August 2010
pages: 468-471

Percutaneous Implantation of the Self-Expandable CoreValve for High Risk Patients with Severe Aortic Valve Stenosis: Early Israeli Experience

    Summary

    Background: The prevalence of aortic stenosis increases with advancing age. Once symptoms occur the prognosis in patients with severe aortic stenosis is poor. The current and recommended treatment of choice for these patients is surgical aortic valve replacement. However, many patients, mainly the very elderly and those with major comorbidities, are considered to be at high surgical risk and are therefore denied treatment. Recently, a transcatheter alternative to surgical AVR[1] has emerged.

    Objectives: To describe the first year experience and 30 day outcome of transcatheter aortic self-expandable CoreValve implantation in Israel.

    Methods: Transcatheter aortic valve implantation using the CoreValve system has been performed in Israel since September 2008. In the following year 55 patients underwent CoreValve TAVI[2] in four Israeli centers.

    Results: Patients' mean age was 81.7 ± 7.1 years; there were 35 females and 20 males. The mean valve area by echocardiogram was 0.63 ± 0.16 cm2. The calculated mean logistic Euroscore was 19.3 ± 8%. Following TAVI, mean transvalvular gradient decreased from baseline levels of 51 ± 13 to 9 ± 3 mmHg. The rate of procedural success was 98%. One patient died on the first day post-procedure (1.8%) and all-cause 30 day mortality was 5.5% (3 of 55 patients). One patient had a significant post-procedural aortic regurgitation of > grade 2. Symptomatic improvement was evident in most patients, with reduction in functional capacity grade from 3.2 ± 0.6 at baseline to 1.4 ± 0.7. The most common post-procedural complication was complete heart block, which necessitated permanent pacemaker implantation in 37% of patients.

    Conclusions: The Israeli first year experience of transcatheter aortic valve implantation using the CoreValve self-expandable system demonstrates an effective and safe procedure for the treatment of severe aortic stenosis in patients at high surgical risk.



    [1] AVR = aortic valve replacement

    [2] TAVI = transcatheter aortic valve implantation

    Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
    The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
    © All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

    2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel