May 2013
A. Hamdan, O. Goitein, S. Matetzky, S. Yishay, E. Di Segni, D. Yakubovitch, D. Silverberg, M. Halak, M. Eldar and E. Konen
Background: Over the past few years dobutamine stress magnetic resonance (DSMR) has proven its efficacy as an integral part of the diagnosis of coronary artery disease (CAD).

Objectives: To present the feasibility and safety of DSMR in Israel.

Methods: Thirty patients with suspected or known CAD were studied. DSMR images were acquired during short breath-holds in three short axis views and four-, two-, and three-chamber views. Patients were examined at rest and during a standard dobutamine-atropine protocol. Regional wall motion was assessed in a 16-segment model and the image quality was evaluated using a four-point scale for the visibility of the endocardial border.

Results: In 28 patients (93.4%) DSMR was successfully performed and completed within an average of 55 ± 6 minutes. One patient could not be examined because of claustrophobia and another patient, who was on beta-blockers, did not reach the target heart rate. Image quality was excellent and there was no difference between the rest and stress images in short axis (3.91 ± 0.29 vs. 3.88 ± 0.34, P = 0.13, respectively) and long axis (3.83 ± 0.38 vs. 3.70 ± 0.49, P = 0.09, respectively) views. Segmental intra-observer agreement for wall motion contractility at rest and stress cine images was almost perfect (κ = 0.88, 95% confidence interval = 0.93–0.84, and κ = 0.82, 95% CI = 0.88–0.76) respectively. No serious side effects were observed during DSMR.

Conclusion: The present study confirms the feasibility, safety and excellent image quality of DSMR for the diagnosis of coronary artery diseases.

 

 

April 2007
M. Gorenberg and A. Marmor

Background: Electrocardiography has a very low sensitivity in detecting dobutamine-induced myocardial ischemia.

Objectives: To assess the added diagnostic value of a new cardiac performance index (dP/dtejc) measurement, based on brachial artery flow changes, as compared to standard 12-lead ECG, for detecting dobutamine-nduced myocardial ischemia, using Tc99m-Sestamibi single-photon emission computed tomography as the gold standard of comparison to assess the presence or absence of ischemia.

Methods: The study group comprised 40 patients undergoing Sestamibi-SPECT[1]/dobutamine stress test. Simultaneous measurements of ECG and brachial artery dP/dtejc were performed at each dobutamine level. In 19 of the 40 patients perfusion defects compatible with ischemia were detected on SPECT. The increase in dP/dtejc during infusion of dobutamine in this group was severely impaired as compared to the non-ischemic group. dP/dtejc outcome was combined with the ECG results, giving an ECG-enhanced value, and compared to ECG alone.

Results: The sensitivity improved dramatically from 16% to 79%, positive predictive value increased from 60% to 68% and negative predictive value from 54% to 78%, and specificity decreased from 90% to 67%.
Conclusions: If ECG alone is used for specificity, the combination with dP/dtejc improved the sensitivity of the test and could be a cost-savings alternative to cardiac imaging or perfusion studies to detect myocardial ischemia, especially in patients unable to exercise







[1] SPECT = single-photon emission computed tomography