Alona Bin-Nun MD, Cathy Hammerman MD, Francis B Mimouni MD, Netanel Wasserteil MD, and Yair M. Kasirer MD

Background: Many countries have adopted a mandatory routine pulse oximetry screening of newborn infants to identify babies with otherwise asymptomatic critical congenital heart disease (CCHD).

Objectives: To describe the current status of pulse oximetry CCHD screening in Israel, with a special emphasis on the experience of the Shaare Zedek Medical Center.

Methods: We review the difficulties of the Israeli Medical system with adopting the SaO2 screening, and the preliminary results of the screening at the Shaare Zedek Medical Center, both in terms of protocol compliance and CCHD detection.

Results: Large scale protocol cannot be implemented in one day, and regular quality assessment programs must take place in order to improve protocol compliance and identify the reasons for protocol failures.

Conclusions: Quality control reviews should be conducted soon after implementation of the screening to allow for prompt diagnosis and quick resolution

January 2001
Abraham Matitiau, MD, Einat Birk, MD, Ludmyla Kachko, MD, Leonard C. Blieden, MD and Elchanan Bruckheimer, MB, BS

Background: Secundum atrial septal defect is a common congenital heart defect that causes right heart volume overload and produces symptoms usually after the third decade of life. Treatment until the last few years has been open heart surgery.

Objective: To review our early experience with transcatheter closure of ASD2 using the Amplatzer septal occluder.

Methods: Between November 1999 and February 2000, 20 children and young adults with a median age of 9.1 years (4.2-35.1 years) were referred for transcatheter closure of ASD2. Diagnosis was established by transthoracic echocardiography. Implantation was performed under general anesthesia through the femoral vein with the guidance of transesophageal echocardiography and fluoroscopy. Femoral arterial puncture was performed for blood pressure monitoring during the procedure. The device size chosen was similar to the balloon-stretched diameter of the ASD2.

Results: Implantation was completed successfully in 18 patients. Two patients were referred for elective surgery: one had an unsuitable anatomy for transcatheter closure by TEE in the catheterization laboratory and the device could not implanted properly, the other patient had a large multiperforated septal aneurysm that was retrieved. Mean ASD2 diameter by TTE and TEE was similar (13.9 + 3 mm, 13.4 + 3.5 mm) and mean stretched diameter was 18.3 + 4.3 mm. Mean Qp:Qs (pulmonary flow: systemic flow) was 2.2 + 0.6. Mean fluoroscopy time for the procedure was 14.8 + 4.8 minutes.

The patients were discharged the day after the procedure.

Four patients had a tiny leak immediately post-procedure, and none had a leak at one month follow-up. The only complication was a small pseudoaneurysm of the femoral artery in one patient, that resolved spontaneously.

Conclusion: Transcatheter closure of ASD2 with the Amplatzer septal occluder is a safe and effective alternative to surgical closure. Long-term outcome has to be evaluated.