May 2018
Roman Nevzorov MD, Avital Porter MD, Shanie Mostov DVM, Shirit Kazum MD, Alon Eisen MD, Gustavo Goldenberg MD, Zaza Iakobishvili MD, Jairo Kusniec MD, Gregory Golovchiner MD, Boris Strasberg MD and Moti Haim MD

Background: Gender-related differences (GRD) exist in the outcome of patients with cardiac resynchronization therapy (CRT).

Objectives: To assess GRD in patients who underwent CRT.

Methods: A retrospective cohort of 178 patients who were implanted with a CRT in a tertiary center 2005–2009 was analyzed. Primary outcome was 1 year mortality. Secondary endpoints were readmission and complication rates.

Results: No statistically significant difference was found in 1 year mortality rates (14.6% males vs. 11.8% females, P = 0.7) or in readmission rate (50.7% vs. 41.2%, P = 0.3). The complication rate was only numerically higher in women (14.7% vs. 5.6%, P = 0.09). Men more often had CRT-defibrillator (CRT-D) implants (63.2% vs. 35.3%, P = 0.003) and had a higher rate of ischemic cardiomyopathy (79.2% vs. 38.2%, P < 0.001). There was a trend to higher incidence of ventricular fibrillation/ventricular tachycardia in men before CRT implantation (29.9% vs. 14.7%, P = 0.07%). A higher proportion of men upgraded from implantable cardioverter defibrillator (ICD) to CRT-D, 20.8% vs. 8.8%, P = 0.047. On multivariate model, chronic renal failure was an independent predictor of 1 year mortality (hazard ratio [HR] 3.6; 95% confidence interval [95%CI] 1.4–9.5), CRT-D had a protective effect compared to CRT-pacemaker (HR 0.3, 95%CI 0.12–0.81).

Conclusions: No GRD was found in 1 year mortality or readmission rates in patients treated with CRT. There was a trend toward a higher complication rate in females. Men were implanted more often with CRT-D and more frequently underwent upgrading of ICD to CRT-D.

 

August 2015
Guy Topaz MD, Moti Haim MD, Jairo Kusniec MD, Shirit Kazum MD, Gustavo Goldenberg MD, Gregory Golovchiner MD, Ran Kornowski MD, Boris Strasberg MD and Alon Eisen MD

Background: Cardiac resynchronization therapy (CRT) is a non-pharmacological option for patients with heart failure and interventricular dyssynchrony. Elevated red cell distribution width (RDW) reflects higher size and heterogeneity of erythrocytes and is associated with poor outcome in patients with chronic heart failure. 

Objectives: To examine the association between RDW levels and outcomes after CRT implantation.

Methods: We conducted a cohort analysis of 156 patients (126 men, median age 69.0 years) who underwent CRT implantation in our institution during 2004–2008. RDW was measured at three time points before and after implantation. Primary outcome was defined as all-cause mortality, and secondary outcome as hospital re-admissions. We investigated the association between RDW levels and primary outcome during a median follow-up of 61 months.

Results: Ninety-five patients (60.9%) died during follow-up. Higher baseline RDW levels were associated with all-cause mortality (unadjusted HR 1.35, 95%CI 1.20–1.52, P < 0.001). On multivariate analysis adjusted for clinical, electrocardiographic and laboratory variables, baseline RDW levels were associated with mortality (HR 1.33, 95%CI 1.16–1.53). RDW levels 6 months and 12 months post-implantation were also associated with mortality (HR 1.22, 95%CI 1.08–1.38, P = 0.001; and HR 1.15, 95%CI 1.01–1.32, P = 0.02, respectively). Patients who were re-admitted to hospital during follow-up (n=78) had higher baseline RDW levels as compared to those who were not (14.9%, IQR 14.0, 16.0% vs. 14.3%, IQR 13.7, 15.0%, respectively, P = 0.03). 

Conclusion: An elevated RDW level before and after CRT implantation is independently associated with all-cause mortality. 

 