• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Fri, 05.12.25

Search results


January 2014
Daniel Silverberg, Violeta Glauber, Uri Rimon, Yakubovitch Dmitry, Emanuel- Ronny Reinitz, Basheer Sheick-Yousif, Boris Khaitovich, Jacob Schneiderman and Moshe Halak
Background: Surgery for complex aortic aneurysms (thoracoabdominal, juxtarenal and pseudoaneurysms) is associated with a high morbidity and mortality rate. Branched and fenestrated stent grafts constitute a new technology intended as an alternative treatment for this disease.

Objectives: To describe a single-center experience with fenestrated and branched endografts for the treatment of complex aortic aneurysms.

Methods: We reviewed all cases of complex aortic aneurysms treated with branched or fenestrated devices in our center. Data collected included device specifics, perioperative morbidity and mortality, re-intervention rates and mid-term results.

Results: Between 2007 and 2012 nine patients were treated with branched and fenestrated stent grafts. Mean age was 73 years. Mean aneurysm size was 63 mm. Perioperative mortality was 22% (2/9). During the follow-up, re-interventions were required in 3 patients (33%). Of 34 visceral artery branches 33 remained patent, resulting in a patency rate of 97%. Sac expansion was seen in a single patient due to a large endoleak. No late aneurysm- related deaths occurred.

Conclusions: Branched and fenestrated stent grafts are feasible and relatively safe alternatives for the treatment of complex aortic aneurysms involving the visceral segment. Further research is needed to determine the long-term durability of this new technology. 

March 2008
B. Sheick-Yousif, A. Sheinfield, S. Tager, P. Ghosh, S. Priesman, A.K. Smolinsky and E. Raanani

Background: As the shortcomings of the Bentall operation and its variants in the Marfan syndrome have become apparent, the recent cusp-sparing techniques (remodeling or reimplantation) bear promise of better mid-term and long-term outcomes.

Objective: To examine the results of aortic root surgery in patients with Marfan syndrome.

Methods: During the period March 1994 to September 2007, 220 patients underwent aortic valve-sparing surgery; 20 were Marfan patients (group 1) who were compared with another 20 Marfan patients undergoing composite aortic root replacement (group 2). Fourteen patients had aortic dissection and 26 had thoracic aortic aneurysm. There were 31 males and 9 females with a mean age of 37.9 ± 13.8 years. In group 1, reimplantation was used in 13 patients, remodeling in 4, and aortic valve repair with sinotubular junction replacement in 3. In group 2, a mechanical valve conduit was used. Mean logistic Euroscore was 12.27 ± 14.6% for the whole group, five of whom were emergent cases

Results: Group 2 had more previous cardiac procedures compared to group 1 (9 vs. 2, P = 0.03) and shorter cross-clamp time (122 ± 27.1 vs. 153.9 ± 23.7 minutes, P = 0.0004). Overall mortality was 10%. Early mortality was 10% in group 2 and 5% in group 1(NS). Mean follow-up time was 25 months for group 2 and 53 months for group 1. Three patients were reoperated; all had undergone the remodeling. Five year freedom from reoperation and death was 86% and 90% in group 2 and 70% and 95% in group 1 (P = 0.6, P = 0.6), respectively.

Conclusions: Late survival of patients with Marfan syndrome was similar in both groups. Root reconstruction tends towards a higher incidence of late reoperations if the remodeling technique is used. We now prefer to use the reimplantation technique.
 

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel