• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Sun, 28.04.24

Search results


January 2017
Gustavo Goldenberg MD, Tamir Bental MD, Udi Kadmon MD, Ronit Zabarsky MD, Jairo Kusnick MD, Alon Barsheshet MD, Gregory Golovchiner MD and Boris Strasberg MD

Background: Syncope prognosis varies widely: 1 year mortality may range from 0% in the case of vasovagal events up to 30% in the presence of heart disease. 

Objectives: To assess the outcomes and prognosis of patients with implantable cardiac defibrillator (ICD) and indication of primary prevention and compare patients presenting with or without prior syncope.

Methods: We reviewed the charts of 75 patients who underwent ICD implantation with the indication of primary prevention and history of syncope and compared them to a control group of 80 patients without prior syncope. We assessed the number of ventricular tachycardia (VT), ventricular fibrillation (VF), shock, anti-tachycardia pacing (ATP), and death in each group during the follow-up.

Results: Mean follow-up was 893 days (810–976, 95% confidence interval) (no difference between groups). Patients with prior syncope had a higher ejection fraction (EF) (35.5 ± 12.6 vs. 31.4 ± 8.76, P = 0.02), more episodes of VT (21.3% vs. 3.8%, P = 0.001) and VF (8% vs. 0%, P = 0.01) and also received more electric shocks (18.7% vs. 3.8%, P = 0.004) and ATP (17.3% vs. 6.2%, P = 0.031). There were no differences in inappropriate shocks (6.7% vs. 5%, P = 0.74), in cardiovascular mortality (cumulative 5 year estimate 29.9% vs. 32.2% P = 0.97) and any death (cumulative 5 year estimate 38.1% vs. 48.9% P = 0.18) during the follow-up.

Conclusions: Syncopal patients before ICD implantation seem to have more episodes of VT/VF and shock or ATP. No mortality differences were observed

 

June 2016
Gustavo Goldenberg MD, Tamir Bental MD, Udi Kadmon MD, Ronit Zabarsky MD, Jairo Kusnick MD, Alon Barsheshet MD, Gregory Golovchiner MD and Boris Strasberg MD

Background: Syncope is a common clinical condition spanning from benign to life-threatening diseases. There is sparse information on the outcomes of syncopal patients who received an implantable cardiac defibrillator (ICD) for primary prevention of sudden cardiac death (SCD). 

Objectives: To assess the outcomes and prognosis of patients who underwent implantable cardiac defibrillator (ICD) implantation for primary prevention of SCD and compare them to patients who presented with or without prior syncope.

Methods: We compared the medical records of 75 patients who underwent ICD implantation for primary prevention of SCD and history of syncope to those of a similar group of 80 patients without prior syncope. We assessed the episodes of ventricular tachycardia (VT), ventricular fibrillation (VF), shock, anti-tachycardia pacing (ATP) and mortality in each group during follow-up.

Results: Mean follow-up was 893 days (810–976, 95%CI) (no difference between groups). There was no significant difference in gender or age. Patients with prior syncope had a higher ejection fraction rate (35.5 ± 12.6 vs. 31.4 ± 8.76, P = 0.02), experienced more episodes of VT (21.3% vs. 3.8%, P = 0.001) and VF (8% vs. 0%, P = 0.01), and received more electric shocks (18.7% vs. 3.8%, P = 0.004) and ATP (17.3% vs. 6.2%, P = 0.031). There were no differences in inappropriate shocks (6.7% vs. 5%, P = 0.74), cardiovascular mortality (cumulative 5 year estimate 29.9% vs. 32.2%, P = 0.97) and any death (cumulative 5 year estimate 38.1% vs. 48.9%, P = 0.18).

Conclusions: Patients presenting with syncope before ICD implantation seemed to have more episodes of VT/VF and shock or ATP. No differences in mortality were observed

 

March 2013
A. Shauer, I. Gotsman, A. Keren, D.R. Zwas, Y. Hellman, R. Durst and D. Admon
 Acute myocarditis is one of the most challenging diseases to diagnose and treat in cardiology. The true incidence of the disease is unknown. Viral infection is the most common etiology. Modern techniques have improved the ability to diagnose specific viral pathogens in the myocardium. Currently, parvovirus B19 and adenoviruses are most frequently identified in endomyocardial biopsies. Most patients will recover without sequelae, but a subset of patients will progress to chronic inflammatory and dilated cardiomyopathy. The pathogenesis includes direct viral myocardial damage as well as autoimmune reaction against cardiac epitopes. The clinical manifestations of acute myocarditis vary widely – from asymptomatic changes on electrocardiogram to fulminant heart failure, arrhythmias and sudden cardiac death. Magnetic resonance imaging is emerging as an important tool for the diagnosis and follow-up of patients, and for guidance of endomyocardial biopsy. In the setting of acute myocarditis endomyocardial biopsy is required for the evaluation of patients with a clinical scenario suggestive of giant cell myocarditis and of those who deteriorate despite supportive treatment. Treatment of acute myocarditis is still mainly supportive, except for giant cell myocarditis where immunotherapy has been shown to improve survival. Immunotherapy and specific antiviral treatment have yet to demonstrate definitive clinical efficacy in ongoing clinical trials. This review will focus on the clinical manifestations, the diagnostic approach to the patient with clinically suspected acute myocarditis, and an evidence-based treatment strategy for the acute and chronic form of the disease.

 

August 2012
E. Kadmon, D. Menachemi, J. Kusniec, M. Haim, M. Geist and B. Strasberg

Background: The implantable loop recorder (ILR) is an important tool for the evaluation of unexplained syncope, particularly in cases of rarely occurring arrhythmia.

Objectives: To review the clinical experience of two Israeli medical centers with the ILR. Methods: We reviewed the medical records of patients with unexplained syncope evaluated with the ILR at Rabin Medical Center (2006–2010) and Wolfson Medical Center (2000–2009).

Results: The study group included 75 patients (44 males) followed for 11.9 ± 9.5 months after ILR implantation. Patients’ mean age was 64 ± 20 years. The ILR identified an arrhythmic mechanism of syncope in 20 patients (17 bradyarrhythmias, 3 tachyarrhythmias) and excluded arrhythmias in 12, for a diagnostic yield of 42.7%. It was not diagnostic in 17 patients (22.7%) at the time of explant 26 patients (34.7%) were still in follow-up. In two patients ILR results that were initially negative were reversed by later ILR tracings. The patients with bradyarrhythmias included 9 of 16 (56.3%) with surface electrocardiogram conduction disturbances and 2 of 12 (16.7%) with negative findings on carotid sinus massage. All bradyarrhythmic patients received pacemakers the seven patients for whom post-intervention data were available had no or mild symptoms.

Conclusions: The ILR has a high diagnostic yield. Pre-ILR findings correlating with the ILR results are conduction disturbances (positive predictor of arrhythmia) and negative carotid sinus massage results (negative predictor of arrhythmia). Proper patient instruction is necessary to obtain accurate results. Caution is advised when excluding an arrhythmia on the basis of ILR tracings, and long-term follow-up is warranted.

August 2011
I. Gotsman, D. Zwas, Z. Zemora, R. Jabara, D. Admon, C. Lotan and A. Keren

Background: Patients with heart failure (HF) have a poor prognosis. Heart failure centers with specialized nurse-supervised management programs have been proposed to improve prognosis.

Objectives: To evaluate the clinical outcome of patients with HF treated at a multidisciplinary HF center of Clalit Health Services in Jerusalem in collaboration with Hadassah University Hospital.

Methods: We evaluated clinical outcome including hospitalizations and death in all HF patients followed at the HF center for 1 year.

Results: Altogether, 324 patients were included and followed at the HF center; 58% were males with a mean age of 76 ± 11 years, and 58% were in New York Heart Association (NYHA) functional class 3-4. The overall 1 year survival rate was 91% and the 1 year hospitalization rate 29%. Comparing patients in the HF center to the whole cohort of patients with a diagnosis of HF (N=6618) in Clalit Health Services in Jerusalem demonstrated a similar 1 year survival rate: 91% vs. 89% respectively but with a significantly reduced hospitalization rate: 29% vs. 42% respectively (P < 0.01). Cox regression analysis demonstrated that treatment in the HF center was a significant predictor of reduced hospitalization after adjustment for other predictors (hazard ratio 0.65, 95% confidence interval 0.530.80, P < 0.0001). A subset of patients that was evaluated (N=78) showed significantly increased compliance. NYHA class improved in these patients from a mean of 3.1 ± 0.1 to 2.6 ± 0.1 after treatment (P < 0.0001).

Conclusions: Supervision by dedicated specialized nurses in a HF center increased compliance, improved functional capacity in HF patients, and reduced hospitalization rate. HF centers should be considered part of the standard treatment of patients with symptomatic HF.
 

April 2007
R. Durst, C. Lotan, H. Nassar, M. Gotsman, E. Mor, B. Varshitzki, P. Greganski, R. Jabara, D. Admon, D. Meerkin and M. Mosseri

Background: Femoral artery vascular complications are the most common adverse events following cardiac catheterization. Smaller diameter introducer sheaths and catheters are likely to lower the puncture site complication rate but may hinder visualization.

Objectives: To evaluate the safety and angiographic quality of 4 French catheters.

Methods: The study was designed to simulate real-life operator-based experience. Diagnostic angiography was performed with either 4F or 6F diagnostic catheters; the size of the catheter used in each patient was predetermined by the day of the month. Patients undergoing 4F and 6F diagnostic angiography were ambulated after 4 and 6 hours, respectively. The following technical parameters were recorded by the operator: ease of introducer sheath insertion, ease of coronary intubation, ease of injection, coronary opacification, collateral flow demonstration, and overall assessment. Adverse events were recorded in all patients and included minor bleeding, major bleeding (necessitating blood transfusion), minor hematoma, major hematoma, pseudo-aneurysm formation and arteriovenous fistula.

Results: The study group included 177 patients, of whom 91 were in the 4F arm and 86 in the 6F arm. Demographic and procedural data were similar in both groups. Seventy-seven percent of 6F and 50% of 4F procedures were evaluated as excellent (P < 0.05). This difference was attributed to easier intubation of the coronary ostium and contrast material injection, increased opacification of the coronary arteries, and demonstration of collateral flow with 6F catheters. Complications occurred in 22% of patients treated with 6F catheters and 10% of those treated with 4F catheters (P = 0.11). Of the 50 patients who switched from 4F to 6F 12% had complications. In patients undergoing diagnostic angiography, the complication rate was 10% vs. 27% (most of them minor) in the 4F and 6F groups, respectively (P < 0.05).
Conclusions: Patients catheterized with 4F have fewer complications compared with 6F diagnostic catheters even when ambulated earlier. Although 4F had a reduced quality compared to 6F angiographies, they were evaluated as satisfactory or excellent in quality 85% of the time. 4F catheters have a potential for reduced hospitalization stay and are a good option for primary catheterization in patients not anticipated to undergo coronary intervention

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel