• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Mon, 09.12.24

Search results


April 2024
Dante Antonelli MD, Vladimir Poletaev MD, Vidal Essebag MD, Alexander Feldman MD

Inappropriate implantable cardiac defibrillator (ICD) shock due to electromagnetic interference (EMI) induced by electrocautery is a well-known theoretical association but is rarely reported [1]. We report a case of EMI induced by electrocautery causing inappropriate ICD shock, underlining that, with the use of monopolar cautery, not only the location of the surgery but also electrodispersive pad (EDP) placement may be important to avoid EMI.

June 2023
Dante Antonelli MD, Vladimir Poletaev MD, Alexander Feldman MD

Inappropriate shocks are a serious and still unresolved problem associated with implantable cardioverter defibrillators (ICDs) that have been associated with increased mortality and impairment of quality of life [1] despite advances in device safety. We report a case of electromagnetic interference (EMI) while showering that resulted in an inappropriate ICD discharge.

May 2021
Vladimir Poletaev MD, Dante Antonelli MD, Galina Litskevich MD, and Yoav Turgeman MD

Background: The cold season seems to be a trigger for atrial fibrillation (AF). Some reports are controversial and demonstrate variability according to the climatic characteristics in different regions.

Objective: To analyze whether meteorological factors contribute to seasonal variation of exacerbation of AF diagnosed in patients referred to the emergency department (ED) of our hospital.

Methods: We retrospectively reviewed medical data of consecutive patients admitted to the ED with symptomatic acute onset AF from 1 January 2016 to 31 December 2018. We recorded the mean monthly outdoor temperature, barometric pressure, and relative humidity during the study period.

Results: During the study period, 1492 episodes of AF were recorded. New onset AF were 639 (42.8%) and paroxysmal atrial fibrillation (PAF) were 853 (57.2%) (P = 0.03). The number of overall admission of AF episodes was not distributed uniformly through the year. Incidence of AF episodes peaked during December and was lowest in June (P = 0.049). Of 696 episodes (46.6 %) the patients were hospitalized and for 796 (53.4%) the patients were discharged (0.01). The number of hospitalizations was not distributed uniformly through the year (P = 0.049). The highest number of hospitalizations happened in December and the lowest in May. Outdoor temperature and barometric pressure (but not relative humidity) may mediate a monthly fluctuation in AF episodes with highest number of ED visits in December and the lowest in June.

Conclusions: Meteorological conditions influence exacerbation of AF episodes and hospitalization. Outdoor temperature and barometric pressure may mediate a monthly fluctuation in AF

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel