March 2006
D. Bar-Zohar, B. Sagie, N. Lubezky, M. Blum, J. Klausner and S. Abu-Abeid

Background: Peritoneal dialysis is a widely accepted route for renal replacement. With the advent of endoscopy, many surgical techniques for the prevention of catheter failure have been proposed.

Objectives: To evaluate the outcomes of patients undergoing laparoscopic Tenckhoff catheter implantation, using the pelvic fixation technique.

Methods: Data analysis was retrospective. All procedures were performed under general anesthesia. A double-cuffed catheter was inserted using two 5 mm trocars and one 10 mm trocar, fixing its internal tip to the dome of the bladder and its inner cuff to the fascia. Catheter failure was defined as persistent peritonitis/exit-site/tunnel infection, severe dialysate leak, migration or outflow obstruction.

Results: LTCI[1] was performed in 34 patients. Mean patient age was 65 ± 17 years. In 12 of the 34 patients the indication for LTCI was end-stage renal failure combined with NYHA class IV congestive heart failure. Operative time was 35 ± 15 minutes. A previous laparotomy was performed in 9 patients. Hospital stay was 1.5 ± 0.6 days. The first continuous ambulatory peritoneal dialysis was performed after 20 ± 12 days. Median follow-up time was 13 months. There were several complications, including 5 (14%) exit-site/tunnel infections, 27 episodes (0.05 per patient-month) of bacterial peritonitis, 3 (9%) incisional hernias, 1 case of fatal intraabdominal bleeding, 2 (5.8%) catheter migrations (functionally significant), and 10 (30%) cases of catheter plugging, 8 of which were treated successfully by instillation of urokinase and 2 surgically. A complication-mandated surgery was performed in 8 patients (23.5%). The 1 year failure-free rate of the catheter was 80.8%. One fatal intraabdominal bleeding was recorded.
Conclusions: LTCI is safe, obviating the need for laparotomy in high risk patients. Catheter fixation to the bladder may prevent common mechanical failures







[1] LTCI = laparoscopic Tenckhoff catheter implantation


October 2004
E. Gnessin, P.M. Livneh, J. Baniel and G. Gillon
Background: Sphincter-related incontinence after radical prostatectomy, benign prostatectomy or due to neurogenic disease has a considerable negative impact on quality of life. Artificial urinary sphincter implantation is a mainstay therapeutic option for these patients.

Objectives: To assess patient satisfaction, subjective long-term continence and complications after AMS 800 artificial urinary sphincter implantation.

Methods: The medical records of 34 patients who underwent artificial urinary sphincter implantation for radical prostatectomy (n=23), simple prostatectomy (n=9) or neurogenic disease (n=2) between 1995 and 2003 were studied retrospectively. Median follow-up was 49 months (range 3–102 months). Records were analyzed for urinary sphincter survival and complications. Quality of life and continence assessment was done by mailing an impact questionnaire.

Results: In 4 of the 34 patients (11.7%) the device was removed due to infection. One of the four had surgical revision elsewhere, and the other three were not interested in re-implantation of the device. Two patients (5.9%) underwent revisions due to mechanical failure. One patient died and three patients were not located. Twenty-seven out of a possible 30 patients (88%) completed the questionnaire; 22 (85%) achieved social continence (0–2 pads daily), and one patient had subjective difficulty activating the device. Subjective improvement and patient satisfaction was rated as 4.22 and 4.11, respectively (scale 0 to 5).
Conclusions: Artificial urinary sphincter implantation is an efficacious option for sphincter-related incontinence. This study documents the positive impact of artificial urinary sphincter implantation on quality of life with acceptable complications; these results are comparable to other published studies.