• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Tue, 10.12.24

Original Articles

IMAJ | volume 13

Journal 7, July 2011
pages: 402-407

Impact of Descent and Stay at a Dead Sea Resort (Low Altitude) on Patients with Systolic Congestive Heart Failure and an Implantable Cardioverter Defibrillator

    Summary

    Background: As the lowest natural site on earth (-415 meters), the Dead Sea is unique for its high pressure and oxygen tension in addition to the unparalleled combination of natural resources. Furthermore, its balneotherapeutic resorts have been reported to be beneficial for patients with various chronic diseases.

    Objectives: To evaluate the safety, quality of life (QoL), exercise capacity, heart failure, and arrhythmia parameters in patients with systolic congestive heart failure (SCHF) and implantable cardioverter defibrillator (ICD) following descent and stay at the Dead Sea.

    Methods: The study group comprised patients with SCHF, New York Heart Association functional class II-III after ICD implantation. The following parameters were tested at sea level one week prior to the descent, during a 4 day stay at the Dead Sea, and one week after return: blood pressure, O2 saturation, ejection fraction (echocardiography), weight, B-type natriuretic peptide (BNP), arrhythmias, heart rate, heart rate variability (HRV), and QoL assessed by the Minnesota Living with Heart Failure questionnaire.

    Results: We evaluated 19 patients, age 65.3 ± 9.6 years, of whom 16 (84%) were males and 18 (95%) had ICD-cardiac resynchronization therapy. The trip to and from and the stay at the Dead Sea were uneventful and well tolerated. The QoL score improved by 11 points, and the 6 minute walk increased by 63 meters (P < 0.001). BNP levels slightly increased with no statistical significance. The HRV decreased (P = 0.018). There were no significant changes in blood pressure, weight, O2 saturation or ejection fraction.

    Conclusions: Descent to, ascent from, and stay at the Dead Sea resort are safe and might be beneficial in some aspects for patients with sCHF and an ICD.

     

    Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
    The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
    © All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

    2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel