Main Imaging Features of Crohn's Disease: Agreement between MR-Enterography and CT-Enterography

Click on the icon on the upper right hand side for the article written by Michal M. Amitai MD, Lisa Raviv-Zilka MD, Marjorie Hertz MD, Zippora Erlich PhD, Eli Konen MD, Shomron Ben-Horin MD and Sara Apter MD

IMAJ 2015: 17: May: 293-297
Abstract

Abstract



Background: Only a few studies have compared the accuracy of magnetic resonance enterography (MRE) and computed tomography enterography (CTE) in the diagnosis of Crohn's disease and its complications.



Objectives: To compare the sensitivity of MRE and CTE analysis in their ability to detect, sign-by-sign, 10 classical imaging signs of Crohn's disease.



Methods: The study group comprised 42 biopsy-proven Crohn's disease patients who underwent both CTE and MRE within an average period of 6 weeks. Agreement between the two modalities in detecting the 10 most significant radiological signs of CD was evaluated using the Kappa index. The sensitivity of MRE and CTE was calculated using a standard of reference composed of all the findings seen by CTE and/or MRE. We analyzed MRE and CTE sensitivity separately in two groups, according to the time interval between the examinations.



Results: Agreement between CTE and MRE was more than 70% in 8 of the 10 signs: mural thickening, phlegmon, stenosis, skip lesions, mucosal stratification, fistula, abscess, and creeping fat. The Kappa level of agreement values for CTE versus MRE varied between substantial for phlegmon and skip lesions; moderate for fistula, creeping fat, abscess and mural thickening; and fair for stenosis and dilatation. CTE detected more findings than MRE, except for creeping fat and fistula. There was no significant difference in the sensitivity of CTE and MRE in the two groups defined by the time interval (time < 1.5 and time > 1.5 months) except for detection of dilatation.



Conclusions: Almost all imaging signs of Crohn's disease were detected equally well by both modalities regardless of the time interval between examinations. We therefore consider MRE to be reliable for imaging and follow-up in patients with Crohn's disease who may need recurrent imaging.



 


Download PDF Print