• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Wed, 01.05.24

Search results


December 2014
Yael Weintraub MD, Noa Rabinowicz MD, Penny Hanuka, Michal Rothschild MD, Shulamit Kotzki and Yosef Uziel MD

Background: Intra-articular corticosteroid injection (IACI), a common procedure in juvenile idiopathic arthritis, is usually associated with anxiety and pain. In a previous study, we concluded that nitrous oxide (NO2) provides effective and safe sedation for such procedures. Following the introduction of medical clowns in our hospital, we added them as an integral part of the team performing IACI.

Objectives: To prospectively evaluate the effect of a medical clown on pain perception during intra-articular corticosteroid injection for juvenile idiopathic arthritis using NO2 conscious sedation.

Methods: Patients scheduled for IACI first met and interacted with the medical clown. During the procedure, the rheumatologist and the medical clown worked in parallel to create distraction. NO2 was administered. The patient, parent, physician, medical clown and nurse completed a visual analog scale (0–10) for pain. Change in heart rate ≥ 15% was recorded to evaluate physiologic response to pain and stress.

Results: A total of 46 procedures were performed in 32 children: 23 girls, 9 boys, with a mean age of 10.9 ± 3.6 years. The median visual analog scale pain score for the patients, parents, physicians, medical clown and nurses was 2, 2, 1, 1 and 1, respectively. Five patients had increased heart rate and experienced increased pain.

Conclusions: Active participation of a medical clown during IACI with nitrous oxide for juvenile idiopathic arthritis further decreases pain and stress and results in a positive patient experience. 

February 2010
G. Akler, P. Rotman Pikielny, E. Kots, S. Ish-Shalom and Y. Uziel
June 2008
S. Lieberman, T. Sella, B. Maly, J. Sosna, B. Uziely and M. Sklair-Levy

Background: Occult breast cancer without clinically or mammographically detectable breast tumor is an uncommon presentation.

Objectives: To assess the role of breast MRI in women with metastatic carcinoma and an occult primary, and to define the MRI characteristics of the primary breast tumor.

Methods: This retrospective study evaluated 20 women with metastatic carcinoma of unknown origin who underwent breast MRI between 2000 and 2006. Four women were excluded, leaving 16 in the study group. Probability of malignancy was assessed according to BIRADS classification. MRI performance in detecting lesions and evaluating disease extent was assessed, with the gold standard being surgical or biopsy pathology.

Results: MRI detected suspicious lesions in 15 patients. Lesion size ranged from 0.4 to 7 cm (median 1.5 cm). MRI detected a single lesion in 6 patients (40%), multifocal disease in 3 (20%), multicentric disease in 4 (27%), and bilateral breast lesions in 2 (13%). In 13 patients MRI depicted the primary breast cancer. Initial treatment was surgical in nine; MRI correctly estimated disease extent in 6 (67%), underestimated disease extent in 1 (11%), and overestimated it in 2 (22%). Four patients had biopsy followed by chemotherapy; one had multicentric disease and one had multifocal disease. MR findings were false positive in two patients and false negative in one.

Conclusions: MRI is sensitive in detecting the primary tumor and beneficial in assessing tumor extent. Small size and multiple foci are common features. We suggest that bilateral breast MRI be part of the evaluation of women with metastatic carcinoma and an occult primary.
 

January 2002
Philip J. Hashkes, MD, MSc, Orit Friedland, MD and Yosef Uziel, MD, MSc
November 2001
Yodphat Krausz, MD, Beatrice Uziely, MD, Rafael Nesher, PhD, Roland Chisin, MD and Benjamin Glaser, MD
Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel