• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Fri, 10.05.24

Search results


August 2023
Maya Shina MD, Fabio Kusniec MD, Guy Rozen MD MHA, Shemy Carasso MD FESC FASE, David Planer MD, Ronny Alcalai MD, Liza Grosman-Rimon PhD, Gabby Elbaz-Greener MD MHA DRCPSC, Offer Amir MD FACC

Background: Among the most frequent complications following transcatheter aortic valve replacement (TAVR) is hemostasis imbalance that presents either as thromboembolic or bleeding. Deviations in platelet count (PC) and mean platelet volume (MPV) are markers of hemostasis imbalance.

Objectives: To determine the predictive value of pre- and post-procedural PC and MPV fL 1-year all-cause mortality in patients who underwent TAVR.

Methods: In this population-based study, we included 236 TAVR patients treated at the Tzafon Medical Center between 1 June 2015 and 31 August 2018. Routine blood samples for serum PC levels and MPV fL were taken just before the TAVR and 24-hour post-TAVR. We used backward regression models to evaluate the predictive value of PC and MPV in all-cause mortality in TAVR patients.

Results: In this study cohort, MPV levels 24-hour post-TAVR that were greater than the cohort median of 9 fL (interquartile range 8.5–9.8) were the strongest predictor of 1-year mortality (hazard ratio 1.343, 95% confidence interval 1.059–1.703, P-value 0.015). A statistically significant relationship was seen in the unadjusted regression model as well as after the adjustment for clinical variables.

Conclusions: Serum MPV levels fL 24-hour post-procedure were found to be meaningful markers in predicting 1-year all-cause mortality in patients after TAVR.

May 2023
Yuval Cavari MD, Olga Yermiahu CCRN MHA, Orna Staretz Chacham MD, Guy Beck Rosen MD MHA, Eitan Neeman MD, Isaac Lazar MD

Carbamoyl phosphate synthetase 1 (CPS1; MIM *608307; E.C. 6.3.4.16) is the first rate-limiting enzyme of the urea cycle, an essential metabolic pathway for ammonia detoxification. CPS1 deficiency (CPS1-D) is characterized by severe hyperammonemia during disease exacerbations. During a metabolic crisis, children with CPS1-D are admitted with vomiting, altered mental status, and high serum levels of ammonia. Rapid normalization of ammonia level ameliorates neurological outcome [1,2]. The first-line treatment for hyperammonemia in these patients is ammonia scavengers in combination with citrulline or arginine and high-calorie supplementation while controlling protein intake [1].

March 2022
Lian Bannon MD, Omer Shlezinger MD, Alexandra Nathan MD, Yan Topilsky MD, Ilan Merdler MD MHA, and Eihab Ghantous MD
May 2020
Anas Kadah MD, Tawfik Khoury MD, Wisam Sbeit MD

Background: Buried bumper syndrome (BBS) mostly occurs as a late complication after percutaneous endoscopic gastrostomy (PEG) insertion; however, early BBS has been rarely reported, and the treatment of this condition is still unclear.

Objectives: To evaluate the Seldinger technique for treatment of early BBS after PEG insertion.

Methods: We report two cases of early BBS in two consecutive patients who underwent PEG insertion to maintain oral intake. The first patient was an 83-year-old woman showing Alzheimer type dementia, while the other one was a 76-year-old man who presented with maxillary cancer and treated with radiotherapy followed by left maxillectomy. Post-surgery, he developed progressive difficulty of swallowing due to mouth deformation and treatment related nerve toxicity. The first patient presented with fever and purulent discharge from the gastrostomy insertion site, without ability to rotate or slide the tube through the stoma 10 days after the PEG insertion. The man was admitted to the hospital 5 days following PEG insertion due to a fever of 38°C and peritubal swelling with purulent discharge. In addition, the tube could not rotate or slide through the stoma.

Results: Buried bumper syndrome was demonstrated by computed tomography scan. Gastroscopy and gastrostomy tube replacement was performed successfully according to the Seldinger technique (replacement over guidewire) in both cases. Correct intragastric tube positioning was demonstrated radiographically before resuming tube feeding. The two patients were discharged in good physical condition several days later.

Conclusions: External replacement over guide wire should be considered in such cases.

 

April 2019
Noam Rosen MD, Ofir Chechik MD, Yariv Goldstein MD, Oleg Dolkart PhD, Gavriel Mozes MD, Ofer Rak MD, Alison Dalich BSc, Yossi Geron MD and Eran Maman MD

Background: The number of patients undergoing shoulder arthroplasty is increasing yearly.

Objectives: To evaluate the results of a consecutive series of patients who underwent shoulder replacement for a variety of indications in a single medical center in Israel.

Methods: All shoulder arthroplasties performed in our institution between 2006 and 2015 were retrospectively reviewed. The functional outcomes and satisfaction of 180 shoulder arthroplasties were evaluated for objective and subjective parameters using the American Shoulder and Elbow Surgeons Shoulder Score (ASES), the Disabilities of the Arm, Shoulder and Hand (DASH) outcome measure, and the Short Form Health Survey (SF-12).

Results: The indications for surgery were osteoarthritis (n=35), rotator cuff arthropathy (n=32), fractures (n=99), and other reasons (n=14). The mean follow-up was 52 months. The scores improved markedly among the patients who underwent surgery later in the study period. The mean DASH score before 2012 was 48.8 and improved to 37.2 after 2013. The respective ASES also improved from 54.2 to 68.6. The use of hemiarthroplasty decreased from 85% to 33% as of 2013, while the use of total shoulder arthroplasty increased.

Conclusions: Shoulder arthroplasty represents an effective treatment modality with satisfactory functional outcomes. Our current study demonstrates a shift from hemiarthroplasty to total shoulder arthroplasty, with the number of procedures increasing yearly. Surgeon experience and the expanding volume of operations had a direct positive effect on the functional outcomes of shoulder arthroplasties.

November 2017
Einat Slonimsky MD, Tammar Kushnir PhD, Assaf Kadar MD, Aharon Menahem MD, Alon Grundshtein MD, Steven Velekes MD, Merav Lidar MD, Shmuel Dekel MD and Iris Eshed MD

Background: Metal-on-metal total hip prostheses (MoM-THR) have been shown to produce hypersensitivity reactions and fluid collection (pseudotumor) by the hip as well as high blood metal ions levels (BMILs).

Objectives: To evaluate the magnetic resonance imaging (MRI) signal-to-noise ratio (S/N) in selected body tissues around the hip of patients who underwent MoM hip replacement and to correlate to BMILs.

Methods: Sixty-one MRI hip examinations in 54 post-MoM-THR patients (18 males, 36 females, mean age 65 years) were retrospectively evaluated independently by two readers. The mean S/N ratio in a region of interest was calculated for periprosthetic pseudotumor collection (PPC), the bladder, fat, and muscle on axial T1w, FSE-T2w, and short tau inversion recovery (STIR) sequences on the same location. BMILs were retrieved from patient files.

Results: PPC was detected in 32 patients (52%) with an average volume of 82.48 mm3. BMIL did not correlate with the presence of PPCs but positively correlated with the PPC's volume. A trend for positive correlation was found between BMILs and S/N levels of STIR images for muscle and bladder as well as for PPC and cobalt levels. A trend for correlation was also seen between BMIL with PPC's T1 w S/N.

Conclusions: Alteration of MRI S/N for different hip tissues showed a tendency for correlation with BMILs, possibly suggesting that metal deposition occurs in the PPC as well as in the surrounding tissues and bladder.

February 2016
Amjad Shalabi MD, Ehud Raanani MD, Amihai Shinfeld MD, Rafael Kuperstein MD, Alexander Kogan MD, Alexander Lipey MD, Eyal Nachum MD and Dan Spiegelstein MD

Background: Prolonged life expectancy has increased the number of elderly high risk patients referred for surgical aortic valve replacement (AVR). These referred high risk patients may benefit from sutureless bioprosthesis procedures which reduce mortality and morbidity.

Objectives: To present our initial experience with sutureless aortic bioprotheses, including clinical and echocardiographic results, in elderly high risk patients referred for AVR. 

Methods: Forty patients (15 males, mean age 78 ± 7 years) with symptomatic severe aortic stenosis underwent AVR with the 3F Enable™ or Perceval™ sutureless bioprosthesis during the period December 2012 to May 2014. Mean logistic EuroScore was 10 ± 3%. Echocardiography was performed preoperatively, intraoperatively, at discharge and at follow-up.

Results: There was no in-hospital mortality. Nine patients (22%) underwent minimally invasive AVR via a right anterior mini-thoracotomy and one patient via a J-incision. Four patients underwent concomitant coronary aortic bypass graft, two needed intraoperative repositioning of the valve, one underwent valve exchange due to inappropriate sizing, three (7.5%) had a perioperative stroke with complete resolution of neurologic symptoms, and one patient (2.5%) required permanent pacemaker implantation due to complete atrioventricular block. Mean preoperative and postoperative gradients were 44 ± 14 and 13 ± 5 mmHg, respectively. At follow-up, 82% of patients were in New York Heart Association functional class I and II.

Conclusions: Sutureless AVR can be used safely in elderly high risk patients with relatively low morbidity and mortality. The device can be safely implanted via a minimally invasive incision. Mid-term hemodynamic results are satisfactory, demonstrating significant clinical improvement.

 

December 2015
Orly Goitein MD, Elio Di Segni MD, Yael Eshet MD, Victor Guetta MD, Amit Segev MD, Eyal Nahum MD, Ehud Raanani MD, Eli Konen MD and Ashraf Hamdan MD

Background: Trans-catheter valve implantation (TAVI) is a non-surgical alternative for patients with severe aortic stenosis (AS). Pre-procedural computed tomography angiography (CTA) allows accurate “road mapping,” aortic annulus sizing and the detection of incidental findings.

Objectives: To document the prevalence of non-valvular extra-cardiac findings on CTA prior to TAVI and the impact of these findings on the procedure.  

Methods: Ninety AS patients underwent CTA as part of pre-TAVI planning. Scans extended from the clavicles to the groin. Non-vascular non-valvular findings were documented and graded as follows: (A) significant findings causing TAVI cancellation or postponement, (B) significant findings leading to a change in the TAVI procedure approach, (C) non-significant findings not affecting the TAVI procedure. 

Results: TAVI was planned for 90 patients; their average age was 80.2 ± 7.5 years, 53% were females. Overall, non-valvular cardiac, extra-cardiac and extra-vascular significant and non-significant incidental findings were documented in 97% of scans (87/90). Significant pathologies causing TAVI cancellation or postponement (category A) were documented in 8%. Significant findings affecting the TAVI procedure (category B) were found in 16% of patients. 

Conclusions: Pre-TAVI CTA detected non-valvular extra-vascular pathologies leading to procedure cancellation/postponement or procedure modification in 8% and 16%, respectively. Comprehensive CTA evaluation that acknowledges the importance of such findings is of major importance since it might alter the TAVI procedure or even render it inappropriate. 

 

July 2015
Oded Breuer MD, David Shoseyov MD, Eitan Kerem MD and Rebecca Brooks MD

Background: Treatment using inhaled bronchodilators for asthma with a metered dose inhaler attached to a spacer device (MDI+S) was shown to be as efficient as nebulizers. Nevertheless, nebulizers remain the treatment of choice in most hospitals. 

Objectives: To implement a policy change to improve asthma treatment in pediatric wards and the pediatric emergency department.

Methods: The study was performed in the emergency department and pediatric wards of a university medical center. The study group comprised all children admitted with a diagnosis of asthma necessitating treatment. The medical and nursing staff of both the pediatric emergency department and the pediatric wards was trained how to use metered dose inhalers attached to spacers on a regular basis in asthmatic pediatric patients. At a preset date nebulizers were replaced by spacers and their use was monitored by the supervising physician. Salbutamol was administered by metered dose inhaler (100 μg/puff) attached to a spacer device. The number of puffs was determined by severity of disease according to GINA recommendations. After 2 years the outcome and cost analysis were examined.

Results: During 3 years since the initial policy change 92.5% patients were treated with spacers throughout their hospital stay (emergency department and pediatric ward). Costs were reduced by an estimated 63%. 

Conclusions: In view of its many advantages the replacement of nebulizers by MDI+S for the treatment of acute asthma is feasible, if performed in collaboration with the staff, hospital authority and patients.

 

September 2013
A. L. Schwartz, Y. Topilsky, G. Uretzky, N. Nesher, Y. Ben-Gal, S. Biner, G. Keren and A. Kramer

Background: Stentless aortic bioprostheses were designed to provide improved hemodynamic performance and potentially better survival.

Objectives: To report the outcomes of patients after aortic valve replacement with the Freestyle® stentless bioprosthesis in the Tel Aviv Medical Center followed for ≤ 15 years.

Methods and Results: Between 1997 and 2011, 268 patients underwent primary aortic valve replacement with a Freestyle bioprosthesis, 211 (79%) of them in the sub-coronary position. Mean age, Charlson comorbidity index and Euro-score were 71.0 ± 9.2 years, 4.2 ± 1.5 and 10.2 ± 11 respectively, and 156 (58%) were male. Peak and mean trans-aortic gradient decreased significantly (75.0 ± 29.1 vs. 22.8 ± 9.6 mmHg, P < 0.0001; and 43.4 ± 17.2 vs. 12.1 ± 5.4 mmHg, P < 0.0001 respectively) in 3 months of follow-up. Mean overall follow-up was 4.9 ± 3.1 years and was complete in all patients. In-hospital mortality was 4.1% (n=11) but differed significantly between the first 100 patients operated before 2006 and the last 168 patients operated after January 2006 (8 vs. 3 patients, 8.0% vs. 1.8%, P = 0.01). Overall, 5 and 10 year survival rates were 85 ± 2.5% and 57.2 ± 5.7%, respectively. Five year survival was markedly improved in patients operated after January 2006 compared to those operated in the early years of the experience (92.3 ± 2.3% vs. 76.0 ± 4.4%, P = 0.0009). All the 21 octogenarians operated after January 2006 survived surgery, with excellent 5 year survival (85.1 ± 7.9%). Six patients required reoperation during follow-up: structural valve deterioration in five and endocarditis in one.

Conclusions: Aortic valve replacement with the Freestyle bioprosthesis provides good long-term hemodynamic and clinical outcomes, even in octogenarians. Valve calcification is the major (and rare) mode of valve deterioration leading to reoperation in these patients. 

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel