• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Thu, 25.04.24

Search results


June 2005
A. Kessler, H. Gavriel, S. Zahav, M. Vaiman, N. Shlamkovitch, S. Segal and E. Eviatar
 Background: Fine-needle aspiration biopsy has been well established as a diagnostic technique for selecting patients with thyroid nodules for surgical treatment, thereby reducing the number of unnecessary surgical procedures performed in cases of non-malignant tumors.

Objectives: To evaluate the sensitivity, specificity, accuracy, and positive and negative predictive values of FNAB[1] in cases of a solitary thyroid nodule.

Methods: The preoperative FNAB results of 170 patients who underwent thyroidectomy due to a solitary thyroid nodule were compared retrospectively with the final postoperative pathologic diagnoses.

Results: In cases of a solitary thyroid nodule, FNAB had a sensitivity of 79%, specificity of 98.5%, accuracy of 87%, and positive and negative predictive values of 98.75% and 76.6% respectively. All cases of papillary carcinoma diagnosed by FNAB proved to be malignant on final histology, while 8 of 27 cases of follicular adenoma detected by preoperative FNAB were shown to be malignant on final evaluation of the surgical specimen.

Conclusions: FNAB cytology reduces the incidence of thyroidectomy since this method has excellent specificity and sensitivity and a low rate of false-negative results. It proved to be cost-effective and is recommended as the first tool in the diagnostic workup in patients with thyroid nodules.


 





[1] FNAB = fine-needle aspiration biopsy


April 2005
January 2005
L. Appelbaum, R. Lederman, R. Agid and E. Libson

Background: Involvement of the liver by lymphoma is almost always secondary. A definite diagnosis can be made only after histologic examination. Recently, there has been a trend to replace surgical biopsies with percutaneous core-needle biopsies for the diagnosis of lymphoproliferative disorders.

Objectives: To describe our experience with percutaneous image-guided needle biopsies of the liver in 15 cases of primary and secondary hepatic lymphoma.

Methods: Between 1997 and 2002, 15 of all the percutaneous computerized tomography-guided core-needle liver biopsies performed at our institution yielded the diagnosis of lymphoma. We retrospectively reviewed the medical records of these patients.

Results: Seven patients had primary hepatic lymphoma (all non-Hodgkin’s lymphoma), and eight had secondary (three Hodgkin`s disease and five non-Hodgkin’s lymphoma). No major complications were caused by the percutaneous biopsies, and all biopsies were diagnostic. The imaging findings were non-specific but were characteristic and similar to previously described series. Imaging demonstrated hypodense lesions by CT, or hypoechoic or anechoic lesions by ultrasound in all but two cases in which hilar lesions resulted in biliary dilatation, both demonstrated by ultrasound

Conclusions: Review of our primary cases indicated no association with cirrhosis or AIDS in contradistinction to the worldwide experience. There were no significant complications in the 15 patients in the study, and a definite diagnosis of lymphoma was made in all the cases with no need to proceed to surgical biopsy. We highly recommend image-guided core-needle biopsy of the liver as a reliable and useful tool for the diagnosis of hepatic lymphoma.

 
 

June 2004
M. Carmon, L. Rivkin, R. Abu-Dalo, M. Goldberg, I. Hadas, I. Zagal, S. Strano, A. Fisher and O. Lernau

Background: Major efforts are being directed at the early diagnosis of breast cancer. The diagnosis rate of non-palpable tumors is steadily growing as a result of increased screening by mammography. In most patients with non-palpable lesions, percutaneous image-guided biopsies have replaced wire localization with surgical excision for obtaining tissue diagnosis. In recent years the Israel Ministry of Health initiated a mammograpy screening program. Percutaneous image-guided biopsies have also become widely available.

Objective: To assess the impact of these changes on breast cancer surgical treatment in our hospital.

Methods: The charts of 483 patients operated on in our department for primary breast carcinoma during the years 1997 to mid-2001 were reviewed. Data on the mode of diagnosis, tumor stage, resection margins, and number and types of operations were recorded and analyzed. The term non-palpable tumors relates to tumors necessitating wire localization for surgical excision.

Results: The percentage of patients diagnosed with non-palpable tumors rose from 16.2% in 1997 to 47.4% in 2001, with an average size of 2.6 cm for palpable and 1.7 cm for non-palpable tumors. The rate of preoperative diagnosis for non-palpable tumors rose from 6.2% in 1997 to 96.4% in 2001. The rate of involved or very close margins was reduced by 73% in the patient group diagnosed preoperatively as compared to those without a preoperative diagnosis (10.6% vs. 39.4%). Finally, the percentage of patients who had two operations fell from 56.2% in 1997 to 11.1% in 2001.

Conclusions: The mammography screening program in Jerusalem in 1997–2001 was effective in increasing the relative percentage of non-palpable breast cancers with reduced tumor size at diagnosis. The improved availability of preoperative tissue diagnosis in these patients reduced the number of surgical procedures needed.

August 2003
A. Mahajna, D.D. Hershko, S. Israelit, A. Abu-Salih, Z. Keidar and M.M. Krausz

Background: The histologic status of axillary lymph nodes is one of the most important prognostic factors in breast cancer, influencing the management of these patients. Axillary lymph node dissection was traditionally performed in all patients to obtain this information but this procedure carries a considerable rate of complications. Recently, sentinel lymph node biopsy has emerged as an accurate and minimally invasive tool for predicting the axillary nodal status and has become the standard of care in selected patients with breast cancer.

Objective: To examine the accuracy of SLN[1] biopsies performed by surgical residents during surgical resident training.

Methods: This prospective, randomized controlled study included 100 consecutive patients with clinically early breast cancer (T1-T2, N0, M0) study. Lymphatic mapping was performed using radiotracers, blue dye, or both. Formal axillary lymph node dissection completed the operations in all patients. All operations were performed by surgical residents under the supervision of senior surgeons.

Results: The overall rate of identification of sentinel lymph nodes was 92%. The accuracy of SLN biopsy in reflecting the axillary nodal status was 96% with a false negative rate of 5.7%.

Conclusions: Sentinel lymph node biopsy is an accurate method for the evaluation and staging of regional lymph nodes in breast cancer patients. A dedicated instruction program for surgical residents may increase the standard of care and lead to highly trained surgeons in the management of early breast cancer.

_________________________________


[1] SLN = sentinel lymph node

February 2003
N. Maimon and Y. Almog

Patients with a compromised immune system suffer a wide variety of insults. Interstitial lung changes are one of the most common and serious complications in this group of patients. The morbidity rate reaches 50% and up to 90% if endotracheal intubation and mechanical ventilation are necessary. Opportunistic and bacterial infections are common causes of pulmonary infiltrates and must be distinguished from other conditions such as drug reactions, volume overload, pulmonary hemorrhage, and malignant diseases. Accurate and prompt diagnosis of potentially treatable causes can be life-saving. Non-invasive diagnostic methods for evaluation are often of little value, and an invasive procedure - such as bronchoalveolar lavage, transbronchial biopsy or even open lung biopsy - is therefore performed to obtain a histologic diagnosis. Yet, even when a specific diagnosis is made it may not improve the patient’s survival. Numerous textbook and review articles have focused on the management of this condition. The present review attempts to provide a comprehensive and systematic picture of current knowledge and an integrated approach to these challenging patients.

January 2003
J. Issakov, G. Flusser, Y. Kollender, O. Merimsky, B. Lifschitz-Mercer and I. Meller

Background: Imaging-guided core needle biopsy is a well-established technique for the diagnosis of bone and soft tissue tumors and tumor-like lesions in specialized orthopedic oncology centers.

Objective: To present our results of computed tomography-guided core needle biopsy with assessment of the accuracy of the technique.

Methods: Between July 1998 and October 2000, 215 CT-guided core needle biopies were performed and histologically examined in the Unit of Bone and Soft Tissue Pathology, Tel Aviv Sourasky Medical Center. There were 80 soft tissue and 135 bony lesions. All biopsies were performed by the same radiologist and the histologic examination by the same pathologist.  To assess the accuracy of the procedure, we compared the diagnosis at biopsy with the diagnosis after definitive surgery (when available).

Results: Bone core needle biopsy (n = 135) showed malignancy in 89 cases (primary or recurrent bone sarcoma, lymphoma, myeloma, metastatic carcinoma or melanoma). There were 29 benign lesions. In 17 cases the result was inconclusive and an open incisional biopsy was performed. Of the 80 soft tissue biopsies, 35 were malignant (25 soft tissue sarcomas, 6 lymphomas, 4 metastatic carcinomas); 40 were benign (myositis ossificans, neurofibroma, desmoid tumor, schwannoma, hematoma and others), and 5 were inconclusive and followed by an open incisional biopsy. The core needle biopsy histologic diagnosis was compared with that of the definitive surgery and the diagnostic accuracy was 90%. Only three samples initially diagnosed as benign turned out to be malignant. No significant complications occurred during the procedures.

Conclusions: CT-guided CNB[1] of musculoskeletal lesions is a safe and effective procedure that assures sufficient and proper material for histologic examination. The accuracy of this method in our center was 90%. Tumor sampling is extremely important, especially in soft tissue sarcomas, and cores should be taken in different directions, including areas of necrosis. The processing is quick, especially for bone CNB, and diagnosis can be achieved within 24 hours. The material undergoes excellent fixation and the immunostains are reliable.






[1] CNB = core needle biopsy


September 2002
Yaacov Ori, MD, Haim Neuman, MD, Avry Chagnac, MD, Annette Siegal, MD, Ana Tobar, MD, Maxim Itkin, MD, Uzi Gafter, MD, PhD and Asher Korzets, MB, BS

Background: The use of an automated biopsy system for renal biopsy has recently gained popularity, but its safety in single functioning kidneys is unclear.

Objective: To report our experience with the automated system for closed renal biopsy during a 5 year period.

Methods: Eighty-five patients underwent percutaneous native renal biopsy with the automated biopsy gun (16G needle) under real-time ultrasound. They were chronologically divided into two groups: 41 patients (group A), using an older ultrasound machine; and 44 patients (group B), using a newer ultrasound machine. Nine patients biopsied with a manual 14G Tru-cut needle served as the control (group C).

Results: The number of "attempted" passes at the kidney was 4.0 ± 0.1 in group B, 4.7 ± 0.3 in group A (P < 0.05 vs. group B), and 5.8 ± 0.5 in group C (P < 0.01 vs. group B). The number of successful passes did not differ (3.3 ± 0.1, 3.3 ± 0.1, 3.1 ± 0.2). The ratio of "attempted/successful" was 1.28 ± 0.07 in group B, 1.95 ± 0.38 in A, and 1.90 ± 0.21 in C (P < 0.01 vs. B). The number of glomeruli obtained was similar in the three groups. Adequate tissue was obtained in 95%, 98%, and 100%, respectively. Hemoglobin decreased by 4.3 ± 1.1% in group B, 6.9 ± 1.3% in group A, and 11.3 ± 1.8% in group C (P < 0.05 vs. B). Perinephric/subcapsular hematoma occurred in 5 patients (11.4%) in group A (2 taking aspirin), in 2 patients (4.9%) in group B, and in none in group C. The necessity for blood transfusion post-biopsy was similar in all groups. Four of five patients with single functioning kidneys (one in group A and four in group B) had uneventful biopsies, and adequate tissue was obtained in three.

Conclusions: The use of the automated biopsy gun is effective, safe and has a low rate of major complications. It may be used safely in single functioning kidneys.

June 2002
Ron Reshef, MD, Wisam Sbeit, MD and Jesse Lachter, MD
January 2002
Nirit Lev, MD, Shalom Michowiz, MD, Edna Inbar, MD, Claire I. Coire, MD, Silvio Pitlik, MD and Eldad Melamed, MD
January 2001
Ofer Levy, MD, Marcel Topilski, MD, Eli Brazowski, MD, Michael Yaron, MD and Moshe Tishler, MD
Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel