• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Sat, 07.12.24

Search results


September 2022
Ronny Ben-Avi MD, Alex Sorkin MD, Roy Nadler MD, Avishai M. Tsur MD, Shaul Gelikas MD MBA, Jacob Chen MD MHA, and Avi Benov MD MHA; and Israel Trauma Group

Background: Chest trauma is among the most common types of trauma, corresponding to 10% of trauma patients admitted to hospitals. In the military setting, thoracic trauma was reported as a significant cause of death. With well-timed treatment, chest trauma is regarded as survivable. Emergency thoracotomy (ET) is considered when the patient with trauma to the chest needs immediate resuscitation. Survival rate is reported as low as 1% in some reports and 20% in others. The survival rate depends on injury mechanism, protocols for intervention, and other decompressive procedures.

Objectives: To determine parameters that may impact survival of ET.

Methods: We conducted a retrospective cohort study to compare prehospital and in-hospital data regarding ET in the emergency department (ED) versus the operating room (OR).

Results: Between 2009 and 2017, 6532 casualties presented to the ED; 1125 with trauma to the chest. Fifty-four of those with chest trauma underwent ET in the hospital (4.8%), 22 (41%) in the ED, and 32 (59%) in the OR. The overall mortality of the ET subgroup was 48%. With regard to thoracotomies, 19/22 of patients (86%) who underwent ET in the ED died compared to 2/28 in the OR (13%).

Conclusions: Utilizing ET after chest trauma with appropriate clinical indications, well-trained personnel, and prompt transportation poses a significant challenge, but may be associated with better survival than that reported previously with military casualties. Adoption of indications and timed allocation to the OR may improve outcomes with chest trauma casualties.

July 2018
Eilon Ram MD, Leonid Sternik MD, Alexander Lipey MD, Sagit Ben Zekry MD, Ronny Ben-Avi MD, Yaron Moshkovitz MD and Ehud Raanani MD

Background: Unicuspid and bicuspid aortic valve (BAV) are congenital cardiac anomalies associated with valvular dysfunction and aortopathies occurring at a young age.

Objectives: To evaluate our experience with aortic valve repair (AVr) in patients with bicuspid or unicuspid aortic valves.

Methods: Eighty patients with BAV or unicuspid aortic valve (UAV) underwent AVr. Mean patient age was 42 ± 14 years and 94% were male. Surgical technique included: aortic root replacement with or without cusp repair in 43 patients (53%), replacement of the ascending aorta at the height of the sino-tubular junction with or without cusp repair in 15 patients (19%), and isolated cusp repair in 22 patients (28%).

Results: The anatomical structure of the aortic valve was bicuspid in 68 (85%) and unicuspid in 12 patients (15%). Survival rate was 100% at 5 years of follow-up. Eleven patients (13.7%) underwent reoperation, 8 of whom presented with recurrent symptomatic aortic insufficiency (AI). Late echocardiography in the remaining 69 patients revealed mild AI in 63 patients, moderate recurrent AI in 4, and severe recurrent AI in 2. Relief from recurrent severe AI or reoperations was significantly lower in patients who underwent cusp repair compared with those who did not (P = 0.05). Furthermore, the use of pericardial patch augmentation for the repair was a predictor for recurrence (P = 0.05).

Conclusions: AVr in patients with BAV or UAV is a safe procedure with low morbidity and mortality rates. The use of a pericardial patch augmentation was associated with higher repair failure.

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel