• IMA sites
  • IMAJ services
  • IMA journals
  • Follow us
  • Alternate Text Alternate Text
עמוד בית
Sun, 02.06.24

Search results


November 2011
A. Golan, R. Marco, H. Raz, E. Shany

Background: Neonatal cerebral imaging is a sensitive technique for evaluating brain injury in the neonatal period. When performing computed tomography or magnetic resonance imaging, sedation is needed to prevent motion artifacts. However, general anesthesia in neonates carries significant risks and requires a complex logistic approach that often limits the use of these modalities. The development of infant immobilizers now enables imaging without general anesthesia and significantly increases clinical and research investigational opportunities.

Objectives: To assess the efficacy of the infant immobilizer instead of general anesthesia for infants undergoing imaging.

Methods: The study group comprised all infants born over a 1 year period at Soroka University Medical Center who required imaging such as MRI, CT or bone scans. A MedVac Vacuum Splint infant immobilizer was used in all infants to prevent motion during imaging. The success rate of a single scan and the need for general anesthesia were assessed.  

Results: Forty infants were examined during 1 year. The studies included 15 CT scans, 25 MRIs and 1 bone scan. The infants’ gestational age at birth was 27–40 weeks and the examinations were performed at ages ranging from delivery to 6 months old. All imaging was successful and none of the infants required general anesthesia.

Conclusions: An infant immobilizer should be used for imaging of newborns. Since this method carries a low risk and has a high success rate, general anesthesia in newborns is justified only when this non-invasive procedure fails.
 

October 2011
D. Shaham, N.R. Bogot, G. Aviram, L. Guralnik, S. Lieberman, L. Copel, J. Sosna, A.E. Moses, I. Grotto and D. Engelhard



Background:
An outbreak of respiratory illness caused by a novel swine-origin influenza virus (influenza A/H1N1 2009) that began in Mexico was declared a global pandemic by the World Health Organization in June 2009. The pandemic affected many countries, including Israel.

Objectives: To compare the course of chest radiographic and computed tomography findings in patients who survived and those who died following admission to the intensive care unit (ICU) or intubation due to severe laboratory-confirmed swine-origin influenza A/H1N1 2009.

Methods: We retrospectively reviewed the patient records (267 radiographs, 8 CTs) of 22 patients (10 males, 12 females) aged 3.5–66 years (median 34) with confirmed influenza A/H1N1 2009, admitted to the ICU and/or intubated in five major Israeli medical centers during the period July–November 2009. We recorded demographic, clinical, and imaging findings –including pattern of opacification, extent, laterality, distribution, zone of findings, and presence/absence of nodular opacities– at initial radiography and during the course of disease, and compared the findings of survivors and non-survivors. Statistical significance was calculated using the Wilcoxon (continuous variables) and Fisher's exact tests (categorical variables).

Results: The most common findings on the initial chest radiography were airspace opacities, which were multifocal in 17patients (77%) and bilateral in 16 (73%), in the lower or lower and middle lung zones in 19 patients (86%). Large airspace nodules with indistinct margins were seen in 8 patients (36%). Twelve patients survived, 10 died. Patients who died had multiple background illnesses and were significantly older than survivors (P = 0.006). Radiologic findings for the two groups were not significantly different.

Conclusion: Airspace opacities, often with nodular appearance, were the most common findings among patients with severeinfluenza A/H1N1 2009. The course of radiologic findings was similar in patients with severe influenza A/H1N1 2009 whosurvived and those who died.

July 2011
K. Machol, A. Vivante, M. Rubinsthein, B. Dekel, Joseph Danieli and G. Paret
December 2010
A. Kapiev, I. Rabin, R. Lavy, B. Chikman, Z. Shapira, H. Kais, N. Poluksht, Y. Amsalam, Z. Halpern, I. Markon, I. Wassermann and A. Halevy

Background: Gastric cancer continues to be a leading cause of cancer death. The treatment approach varies, and preoperative staging is therefore crucial since an exploratory laparotomy for unresectable gastric cancer will be followed by an unacceptably high morbidity and mortality rate.

Objectives: To assess the added value of diagnostic laparoscopy to conventional methods of diagnosis such as computed tomography in avoiding unnecessary laparotomies.

Methods: A retrospective study on 78 patients scheduled for curative gastrectomy based on CT staging was conducted. DL[1] was performed prior to exploratory laparotomy.

Results: In 23 of 78 patients (29.5%), unexpected peritoneal spread not detected on preoperative CT was found. Fifty-five patients underwent radical gastrectomy, 15 patients were referred for downstaging and 8 patients underwent a palliative procedure.

Conclusions: Based on our results, DL should be considered in all gastric cancer patients scheduled for curative gastrectomy.






[1] DL = diagnostic laparoscopy


August 2010
A. Klein-Kremer, H. Jassar, A. Nachtigal and A. Rauf Zeina
July 2010
O. Halshtok, O. Goitein, R. Abu Sham'a, H. Granit, M. Glikson and E. Konen
Background: Until recently, cardiac pacemakers and implantable cardioverter defibrillators were considered an absolute contraindication for magnetic resonance imaging. Given the significant increase in implanting such devices, these contraindications will preclude MRI scanning in a large patient population. Several recent reports have addressed the safety and feasibility of MRI in the presence of cardiac implantable devices.

Objectives: To summarize our experience with MRI scanning in the presence of pacemakers and implantable cardioverter defibrillators.

Methods: Eighteen patients (15 males and 3 females, median 59) were scanned using a 1.5 T MRI scanner. A clinical discussion was held to verify the absolute medical necessity of the study before performing the scan. Scan supervision included device interrogation and programming beforehand, patient monitoring during, and device interrogation and reprogramming after the scan. Full resuscitation equipment was available outside the MRI suite.

Results: Thirty-four scans were performed, and all but one were of diagnostic quality. Anatomic regions included the brain (N=26), cervical spine (N=2), lumbar spine (N=1), cardiac (N=2), abdomen (N=1), abdomen and pelvis (N=1) and pelvis (N=1). None of the patients reported any side effects and no life-threatening events occurred during or following the scans. Five cases of device spontaneous reversion to backup mode were recorded (four in the same patient). Device replacement was not required in any patient.

Conclusions: In this small cohort of patients MRI scanning in the presence of cardiac implantable devices was safe. MRI in these patients is feasible although not recommended for routine scans. Scans should be considered on a case-to-case basis and performed in a dedicated specialized setup.

 

June 2010
R. Beigel, D. Oieru, O. Goitein, P. Chouraqui, M.S. Feinberg, S. Brosh, E. Asher, E. Konen, A. Shamiss, M. Eldar, H. Hod, J. Or and S. Matetzky

Background: Many patients present to the emergency department with chest pain. While in most of them chest pain represents a benign complaint, in some patients it underlies a life-threatening illness.

Objectives: To assess the routine evaluation of patients presenting to the ED[1] with acute chest pain via the utilization of a cardiologist-based chest pain unit using different non-invasive imaging modalities.

Methods: We evaluated the records of 1055 consecutive patients who presented to the ED with complaints of chest pain and were admitted to the CPU[2]. After an observation period and according to the decision of the attending cardiologist, patients underwent myocardial perfusion scintigraphy, multidetector computed tomography, or stress echocardiography.

Results: The CPU attending cardiologist did not prescribe non-invasive evaluation for 108 of the 1055 patients, who were either admitted (58 patients) or discharged (50 patients) after an observation period. Of those remaining, 445 patients underwent MDCT[3], 444 MPS[4], and 58 stress echocardiography. Altogether, 907 patients (86%) were discharged from the CPU. During an average period of 236 ± 223 days, 25 patients (3.1%) were readmitted due to chest pain of suspected cardiac origin, and only 8 patients (0.9%) suffered a major adverse cardiovascular event.

Conclusions: Utilization of the CPU enabled a rapid and thorough evaluation of the patients’ primary complaint, thereby reducing hospitalization costs and occupancy on the one hand and avoiding misdiagnosis in discharged patients on the other.

 

[1] ED = emergency department

[2] CPU = chest pain unit

[3] MDCT = multidetector computed tomography

[4] MPS = myocardial perfusion scintigraphy

May 2010
A. Stepansky, A. Halevy and Y. Ziv

Background: An accurate preoperative definition of tumor and lymph node status is needed for reaching the correct decision regarding rectal cancer treatment. Transrectal ultrasonography is the most commonly used diagnostic modality for the local staging of rectal cancer.

Objectives: To determine the accuracy of TRUS[1] in the staging of rectal cancer.

Methods: We conducted a retrospective study on 95 patients evaluated by TRUS. The rectum was subdivided into two parts (lower and upper).

Results: Sixty patients underwent radical surgery. Of these, 34 received no preoperative chemo-irradiation owing to µT1, µT2 tumor or the patient’s choice (neo-adjuvant treatment was suggested to patients with adenocarcinoma that proved to be µT3). The overall accuracy rate was 80% for T stage. Overstaging was found in 13.3% and understaging in 6.7%.The N-stage was correctly assessed in 70%. The overall accuracy rate for tumors was 73.9% in the lower part and 90.9% in the upper. A trend towards a lower accuracy rate for low-lying tumors compared to high-located rectal tumors was found (P = 0.532), which did not reach statistical significance.

Conclusions: TRUS gave better results for T1 and T3 stage rectal tumors but was inaccurate for stage T2, indicating the possible need for local excision in order to base the final treatment for T2 tumors on pathologic staging.

[1] TRUS = transrectal ultrasonography
 

August 2009
G. Aviram, R. Mohr, R. Sharony, B. Medalion, A. Kramer and G. Uretzky

Background: Injury to patent grafts or cardiac chambers may occur during reoperation after coronary artery bypass grafting. Preoperative spatial localization of bypass grafts with computed tomography may improve the safety of these procedures.

Objectives: To characterize patients who undergo CT before repeat operations after previous coronary artery bypass grafting, and evaluate its benefit in terms of surgical outcome.

Methods: We compared 28 patients who underwent cardiac gated CT angiography before reoperation (CT group) to 45 re-do patients who were not evaluated with CT (no‑CT group).

Results: The two groups were similar in most preoperative and operative characteristics. The CT group, however, included more patients with patent saphenous vein grafts and fewer with emergency operations, acute myocardial infarction and need for intraaortic balloon pump support. During mid-sternotomy, there was no injury to grafts in the CT group, while there were two patent grafts and three right ventricular injuries in the no-CT group. There was no significant difference in perioperative mortality (3.6% vs. 8.9%). The overall complication rate in the CT group was 21.4% compared to 42.2% in the no‑CT group (P = 0.07). The only independent predictors of postoperative complications were diabetes mellitus, preoperative stroke and preoperative acute MI[1].

Conclusions: The patency and proximity of patent grafts to the sternum are well demonstrated by multidetector CT and may provide the surgeon with an important roadmap to avoid potential graft injury. A statistical trend towards reduced complications rate was demonstrated among patients who underwent CT angiography before their repeat cardiac operation. Larger series are required to demonstrate a statistically validated complication-free survival benefit of preoperative CT before repeat cardiac surgery.






[1] MI = myocardial infarction



 
T. Friedman, J. Golan, A. Shalom and M. Westreich

Background: Due to the absence of accurate tools and appropriate photographic material there is a paucity of objective studies on facial aging in the modern literature.

Objectives: To measure changes in two elements of the face: brow ptosis and cheek mass migration, using an objective tool that we developed, which we then used to evaluate facial aging in two subjects, studying serial professional photographs over a 25 year period.

Methods: We studied the photographic atlas of the "Brown Sisters," a record of the yearly group photograph of four sisters, taken by the photographer Nicolas Nixon. For technical reasons, only two of the sisters fulfilled the criteria we set for the study. We used the interpupillary distance of each photograph studied to standardize the brow height and cheek mass distance from the interpupillary line.

Results: We observed progressive medial brow descent occurring at about the age of 30, with apparent stabilization thereafter. In contrast, there was a continuous process of lateral brow descent through the years. A process of gradual cheek mass descent was noted in the second half of the third decade.

Conclusions: Our results indicate that the dynamic brow changes start in the second half of the third decade, with more significant lateral brow descent than medial brow descent. The cheek mass reflective point moves in an inferior-lateral direction. The tool we developed can be used to follow aging changes and postoperative results, thereby helping the surgeon achieve true rejuvenation surgery.

May 2009
R. Eliahou, T. Sella, T. Allweis, S. Yaacov, E. Libson and M. Sklair-Levy

Background: Magnetic resonance imaging of the breast has emerged as a valuable imaging tool in addition to conventional imaging modalities. It has high sensitivity for malignant lesions, and can detect mammographically, sonographically and clinically occult cancers. “MR only” lesions are best biopsied under MR guidance; however, this may be a challenging task.

Objectives:  To evaluate our initial clinical experience with MR-guided core needle breast biopsy and MR-guided needle localization.

Methods: We retrospectively evaluated 81 women with 97 lesions, who were scheduled for guided core needle biopsy or MR-guided needle localization followed by surgery. Lesions were categorized as malignant, high risk, or benign according to the BI- RADS MR classification system. MR findings were compared with final histopathology or with follow-up imaging findings.

Results: Fifteen (16%) lesions were malignant (9 invasive ductal carcinoma, 2 invasive lobular carcinoma, 4 ductal carcinoma in situ); 7 (7%) lesions were high risk (4 atypical ductal hyperplasia, 3 radial scars); 75 (77%) lesions were benign, mainly fibrocystic changes. Other benign findings were sclerosing adenosis, pseudoangiomatous stromal hyperplasia, fat necrosis, intraductal papilloma, fibroadenoma, capillary hemangioma, and florid ductal hyperplasia. No major complications were encountered.
Conclusions: MR-guided interventional procedures of the breast are accurate, safe and feasible methods for sampling breast lesions detected only by MR and have become a significant tool in the management of certain patients.

Legal Disclaimer: The information contained in this website is provided for informational purposes only, and should not be construed as legal or medical advice on any matter.
The IMA is not responsible for and expressly disclaims liability for damages of any kind arising from the use of or reliance on information contained within the site.
© All rights to information on this site are reserved and are the property of the Israeli Medical Association. Privacy policy

2 Twin Towers, 35 Jabotinsky, POB 4292, Ramat Gan 5251108 Israel